Movement EEG Classification Using Parallel Hidden Markov Models
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00301765" target="_blank" >RIV/68407700:21230/16:00301765 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/AE.2016.7577243" target="_blank" >http://dx.doi.org/10.1109/AE.2016.7577243</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/AE.2016.7577243" target="_blank" >10.1109/AE.2016.7577243</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Movement EEG Classification Using Parallel Hidden Markov Models
Popis výsledku v původním jazyce
In this contribution we examine the use and utility of parallel HMM classification in single-trial movement-EEG classification of index finger reaching and grasping movement. Parallel HMMs allow us to easily utilize the information contained in multiple channels. Using HMM classifier output in parallel from examined EEG channels we have been able to achieve as good a classification score as with single electrode results, further we do not rely on a single electrode giving persistently good results. Our parallel approach has the added benefit of not having to rely on small inter-session variability as it gives very good results with fewer classifier parameters being optimized. Without any classification optimization we can get a score improvement of 11.2% against randomly selected physiologically relevant electrode. If we use subject specific information we can further improve on the reference score by 1%, achieving a classification score of 84.2+-0.7%.
Název v anglickém jazyce
Movement EEG Classification Using Parallel Hidden Markov Models
Popis výsledku anglicky
In this contribution we examine the use and utility of parallel HMM classification in single-trial movement-EEG classification of index finger reaching and grasping movement. Parallel HMMs allow us to easily utilize the information contained in multiple channels. Using HMM classifier output in parallel from examined EEG channels we have been able to achieve as good a classification score as with single electrode results, further we do not rely on a single electrode giving persistently good results. Our parallel approach has the added benefit of not having to rely on small inter-session variability as it gives very good results with fewer classifier parameters being optimized. Without any classification optimization we can get a score improvement of 11.2% against randomly selected physiologically relevant electrode. If we use subject specific information we can further improve on the reference score by 1%, achieving a classification score of 84.2+-0.7%.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2016 International Conference on Applied Electronics
ISBN
978-80-261-0601-2
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
65-68
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Plzeň
Datum konání akce
6. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000391238700014