Comparison of home blood pressure measurement devices in real conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00326954" target="_blank" >RIV/68407700:21230/18:00326954 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8531139" target="_blank" >https://ieeexplore.ieee.org/document/8531139</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/HealthCom.2018.8531139" target="_blank" >10.1109/HealthCom.2018.8531139</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of home blood pressure measurement devices in real conditions
Popis výsledku v původním jazyce
Cardiovascular diseases are well known as one of the leading causes of death in developed countries. The hypertension is a significant danger and should be monitored carefully. In recent decades, auscultatory and oscillometric methods become as widely used for blood pressure measurement. In clinical practice, blood pressure measuring devices are evaluated according to validating protocols. Despite these protocols, a market with the automatic devices for home self-measurement of the blood pressure is flooded by a lot of cheap devices with doubtful accuracy. The goal of the study is to compare home blood pressure measurement devices in the real conditions and using the real signals and to show the difference between the values obtained by these devices and by the clinically validated reference device. For each device, the absolute errors of the systolic and the diastolic pressures were evaluated. The obtained results show that the measurement error of these devices could be frequently higher than 5 mmHg and it is necessary to concern with the accuracy of the devices.
Název v anglickém jazyce
Comparison of home blood pressure measurement devices in real conditions
Popis výsledku anglicky
Cardiovascular diseases are well known as one of the leading causes of death in developed countries. The hypertension is a significant danger and should be monitored carefully. In recent decades, auscultatory and oscillometric methods become as widely used for blood pressure measurement. In clinical practice, blood pressure measuring devices are evaluated according to validating protocols. Despite these protocols, a market with the automatic devices for home self-measurement of the blood pressure is flooded by a lot of cheap devices with doubtful accuracy. The goal of the study is to compare home blood pressure measurement devices in the real conditions and using the real signals and to show the difference between the values obtained by these devices and by the clinically validated reference device. For each device, the absolute errors of the systolic and the diastolic pressures were evaluated. The obtained results show that the measurement error of these devices could be frequently higher than 5 mmHg and it is necessary to concern with the accuracy of the devices.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 IEEE 20th International Conference on e-Health Networking, Applications and Services (Healthcom)
ISBN
978-1-5386-4294-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Ostrava
Datum konání akce
17. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—