Comparison of Home Blood Pressure Measurement Devices on Artificial Signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00321858" target="_blank" >RIV/68407700:21230/19:00321858 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1007/978-981-10-9038-7_174" target="_blank" >https://doi.org/10.1007/978-981-10-9038-7_174</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-9038-7_174" target="_blank" >10.1007/978-981-10-9038-7_174</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Home Blood Pressure Measurement Devices on Artificial Signals
Popis výsledku v původním jazyce
Cardiovascular diseases are well known as one of the leading causes of death in developed countries. The hypertension is a significant danger and should be monitor carefully. In recent decades, auscultatory and oscillometric methods become as widely used for blood pressure measurement. In clinical practice, blood pressure measuring devices are evaluated according to validating protocols. Despite these protocols, a market with the automatic devices for home self-measurement of the blood pressure is flooded by a lot of cheap devices with doubtful accuracy. The aim of this study is to compare selected devices for the self-measurement in the home conditions. The devices were evaluated using the blood pressure simulators. For each device and each type of blood pressure signal, the absolute and the relative errors of the diastolic and the systolic pressures were evaluated. The obtained results show that the measurement error of these devices could be frequently higher than 5 mmHg and it is necessary to concern with the accuracy of the devices.
Název v anglickém jazyce
Comparison of Home Blood Pressure Measurement Devices on Artificial Signals
Popis výsledku anglicky
Cardiovascular diseases are well known as one of the leading causes of death in developed countries. The hypertension is a significant danger and should be monitor carefully. In recent decades, auscultatory and oscillometric methods become as widely used for blood pressure measurement. In clinical practice, blood pressure measuring devices are evaluated according to validating protocols. Despite these protocols, a market with the automatic devices for home self-measurement of the blood pressure is flooded by a lot of cheap devices with doubtful accuracy. The aim of this study is to compare selected devices for the self-measurement in the home conditions. The devices were evaluated using the blood pressure simulators. For each device and each type of blood pressure signal, the absolute and the relative errors of the diastolic and the systolic pressures were evaluated. The obtained results show that the measurement error of these devices could be frequently higher than 5 mmHg and it is necessary to concern with the accuracy of the devices.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Congress on Medical Physics and Biomedical Engineering 2018 (Vol. 2)
ISBN
978-981-10-9037-0
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
941-944
Název nakladatele
Springer Nature Singapore Pte Ltd.
Místo vydání
—
Místo konání akce
Prague
Datum konání akce
3. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000449742700174