STUDY ON A RELIABILITY OF HEART RATE MEASUREMENT USING AUTOMATIC TONOMETERS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00326955" target="_blank" >RIV/68407700:21230/18:00326955 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
STUDY ON A RELIABILITY OF HEART RATE MEASUREMENT USING AUTOMATIC TONOMETERS
Popis výsledku v původním jazyce
A home blood pressure measurement device typically indicates heart rate besides the systolic and diastolic blood pressure. While the accuracy of blood pressure measurement is evaluated using the international protocols (AAMI or BHS protocol), the accuracy of heart rate measurement is not systematically evaluated. The goal of the study is to compare selected home blood pressure measurement devices when measuring HR. The devices available in the global market with the different methods of the measurement have been selected for the comparison – electronic tonometers Hartmann Digital HG160) and HuBDIC HBP-1520 and wrist cuff device Omron R7. As a reference device, the NONIN Onyx II 9550 has been used. The study shows that the blood pressure measurement devices for self-measurement in home conditions provide the values with the absolute error lower than 5 bpm in most cases. The averaged values of the absolute error for all devices are even less than 1 bpm.
Název v anglickém jazyce
STUDY ON A RELIABILITY OF HEART RATE MEASUREMENT USING AUTOMATIC TONOMETERS
Popis výsledku anglicky
A home blood pressure measurement device typically indicates heart rate besides the systolic and diastolic blood pressure. While the accuracy of blood pressure measurement is evaluated using the international protocols (AAMI or BHS protocol), the accuracy of heart rate measurement is not systematically evaluated. The goal of the study is to compare selected home blood pressure measurement devices when measuring HR. The devices available in the global market with the different methods of the measurement have been selected for the comparison – electronic tonometers Hartmann Digital HG160) and HuBDIC HBP-1520 and wrist cuff device Omron R7. As a reference device, the NONIN Onyx II 9550 has been used. The study shows that the blood pressure measurement devices for self-measurement in home conditions provide the values with the absolute error lower than 5 bpm in most cases. The averaged values of the absolute error for all devices are even less than 1 bpm.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The Eighth Young Biomedical Engineers and Researchers Conference YBERC 2018
ISBN
978-80-8086-271-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Technical University of Kosice
Místo vydání
Košice
Místo konání akce
Košice
Datum konání akce
3. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—