Ultra-Wideband Temperature Dependent Dielectric Spectroscopy of Blood in the Microwave Frequency Range
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00332776" target="_blank" >RIV/68407700:21230/19:00332776 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/19:00332776
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultra-Wideband Temperature Dependent Dielectric Spectroscopy of Blood in the Microwave Frequency Range
Popis výsledku v původním jazyce
The knowledge of temperature dependent dielectric properties of biological tissue in the microwave frequency range is crucial for medical applications such as microwave temperature monitoring during oncological treatments. This paper deals with temperature dependent dielectric spectroscopy of blood by means of ultra-wideband sensing. We present the results of relative permittivity and conductivity of blood without agents and blood with heparin in the frequency range of 0.5 GHz up to 7 GHz and in the temperature range between 30 degrees C and 50 degrees C. The measurements show that the addition of heparin does not affect the dielectric properties in the considered frequency and temperature range. Furthermore, the measurements are compatible with the few data reported in the literature.
Název v anglickém jazyce
Ultra-Wideband Temperature Dependent Dielectric Spectroscopy of Blood in the Microwave Frequency Range
Popis výsledku anglicky
The knowledge of temperature dependent dielectric properties of biological tissue in the microwave frequency range is crucial for medical applications such as microwave temperature monitoring during oncological treatments. This paper deals with temperature dependent dielectric spectroscopy of blood by means of ultra-wideband sensing. We present the results of relative permittivity and conductivity of blood without agents and blood with heparin in the frequency range of 0.5 GHz up to 7 GHz and in the temperature range between 30 degrees C and 50 degrees C. The measurements show that the addition of heparin does not affect the dielectric properties in the considered frequency and temperature range. Furthermore, the measurements are compatible with the few data reported in the literature.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GC17-20498J" target="_blank" >GC17-20498J: Neinvazivní určení teploty v lidském těle pomocí fyzikálních aspektů ultra-širokopásmového mikrovlnného kanálu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2019 13TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP)
ISBN
9788890701887
ISSN
2164-3342
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE (Institute of Electrical and Electronics Engineers)
Místo vydání
—
Místo konání akce
Krakow
Datum konání akce
31. 3. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000480384702101