Application of solid-phase microextraction arrows for characterizing volatile organic compounds from 3D printing of acrylonitrile-styrene-acrylate filament
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F23%3A00367209" target="_blank" >RIV/68407700:21230/23:00367209 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.chroma.2023.464180" target="_blank" >https://doi.org/10.1016/j.chroma.2023.464180</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2023.464180" target="_blank" >10.1016/j.chroma.2023.464180</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of solid-phase microextraction arrows for characterizing volatile organic compounds from 3D printing of acrylonitrile-styrene-acrylate filament
Popis výsledku v původním jazyce
3D printing is an extensively used manufacturing technique that can pose specific health concerns due to the emission of volatile organic compounds (VOC). Herein, a detailed characterization of 3D printing-related VOC using solid-phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS) is described for the first time. The VOC were extracted in dynamic mode during the printing from the acrylonitrile-styrene-acrylate filament in an environmental chamber. The effect of extraction time on the extraction efficiency of 16 main VOC was studied for four different commercial SPME arrows. The volatile and semivolatile compounds were the most effectively extracted by carbon wide range-containing and polydimethyl siloxane arrows, respectively. The differences in extraction efficiency between arrows were further correlated to the molecular volume, octanol-water partition coefficient, and vapour pressure of observed VOC. The repeatability of SPME arrows towards the main VOC was assessed from static mode measurements of filament in headspace vials. In addition, we performed a group analysis of 57 VOC clas-sified into 15 categories according to their chemical structure. Divinylbenzene-polydimethyl siloxane ar-row turned out to be a good compromise between the total extracted amount and its distribution among tested VOC. Thus, this arrow was used to demonstrate the usefulness of SPME for the qualification of VOC emitted during printing in a real-life environment. A presented methodology can serve as a fast and reliable method for the qualification and semi-quantification of 3D printing-related VOC.
Název v anglickém jazyce
Application of solid-phase microextraction arrows for characterizing volatile organic compounds from 3D printing of acrylonitrile-styrene-acrylate filament
Popis výsledku anglicky
3D printing is an extensively used manufacturing technique that can pose specific health concerns due to the emission of volatile organic compounds (VOC). Herein, a detailed characterization of 3D printing-related VOC using solid-phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS) is described for the first time. The VOC were extracted in dynamic mode during the printing from the acrylonitrile-styrene-acrylate filament in an environmental chamber. The effect of extraction time on the extraction efficiency of 16 main VOC was studied for four different commercial SPME arrows. The volatile and semivolatile compounds were the most effectively extracted by carbon wide range-containing and polydimethyl siloxane arrows, respectively. The differences in extraction efficiency between arrows were further correlated to the molecular volume, octanol-water partition coefficient, and vapour pressure of observed VOC. The repeatability of SPME arrows towards the main VOC was assessed from static mode measurements of filament in headspace vials. In addition, we performed a group analysis of 57 VOC clas-sified into 15 categories according to their chemical structure. Divinylbenzene-polydimethyl siloxane ar-row turned out to be a good compromise between the total extracted amount and its distribution among tested VOC. Thus, this arrow was used to demonstrate the usefulness of SPME for the qualification of VOC emitted during printing in a real-life environment. A presented methodology can serve as a fast and reliable method for the qualification and semi-quantification of 3D printing-related VOC.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Svazek periodika
1705
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
14
Strana od-do
—
Kód UT WoS článku
001032122700001
EID výsledku v databázi Scopus
2-s2.0-85163845963