Separation of curium from americium using composite sorbents and complexing agent solutions: Part 2.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F17%3A00315804" target="_blank" >RIV/68407700:21340/17:00315804 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10967-017-5260-8" target="_blank" >http://dx.doi.org/10.1007/s10967-017-5260-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10967-017-5260-8" target="_blank" >10.1007/s10967-017-5260-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Separation of curium from americium using composite sorbents and complexing agent solutions: Part 2.
Popis výsledku v původním jazyce
TODGA PAN composite sorbent and (PhSO3H)2 BTPhen in nitric acid solution were employed as a system for separation of curium from americium. The influence of aqueous phase composition (complexing agent and nitric acid concentrations) on weight distribution coefficients and Cm/Am separation factor was studied in batch experiments with trace amounts of 241Am and 244Cm. Based on the results obtained, column experiment was designed and conducted. The Cm/Am separation factor of 3.8 ± 0.1 found in batch experiments with TODGA-PAN could be reproduced also in column experiment resulting in good separation of Cm from Am. The efficiency of Cm separation from Am in the TODGA-PAN system was compared with the analogous system with DGA Resin (Triskem International). After separation on a 0.5 mL column (4.7 x 29 mm) the Cm fraction containing 93 % of Cm(III) contained only 3 % of Am(III) in optimum conditions.
Název v anglickém jazyce
Separation of curium from americium using composite sorbents and complexing agent solutions: Part 2.
Popis výsledku anglicky
TODGA PAN composite sorbent and (PhSO3H)2 BTPhen in nitric acid solution were employed as a system for separation of curium from americium. The influence of aqueous phase composition (complexing agent and nitric acid concentrations) on weight distribution coefficients and Cm/Am separation factor was studied in batch experiments with trace amounts of 241Am and 244Cm. Based on the results obtained, column experiment was designed and conducted. The Cm/Am separation factor of 3.8 ± 0.1 found in batch experiments with TODGA-PAN could be reproduced also in column experiment resulting in good separation of Cm from Am. The efficiency of Cm separation from Am in the TODGA-PAN system was compared with the analogous system with DGA Resin (Triskem International). After separation on a 0.5 mL column (4.7 x 29 mm) the Cm fraction containing 93 % of Cm(III) contained only 3 % of Am(III) in optimum conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10402 - Inorganic and nuclear chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
1588-2780
Svazek periodika
312
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
685-689
Kód UT WoS článku
000402173700024
EID výsledku v databázi Scopus
2-s2.0-85018291444