Distribution of the ventilatory pressure in high-frequency oscillatory ventilation in the anatomically based model of the respiratory system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F14%3A00225852" target="_blank" >RIV/68407700:21460/14:00225852 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.degruyter.com/view/j/bmte.2014.59.issue-s1/issue-files/bmte.2014.59.issue-s1.xml" target="_blank" >http://www.degruyter.com/view/j/bmte.2014.59.issue-s1/issue-files/bmte.2014.59.issue-s1.xml</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/bmt-2014-5012" target="_blank" >10.1515/bmt-2014-5012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Distribution of the ventilatory pressure in high-frequency oscillatory ventilation in the anatomically based model of the respiratory system
Popis výsledku v původním jazyce
Amplitude of the pressure oscillations during high-frequency oscillatory ventilation is studied in the model of the respiratory system with five compartments based on the lung morphometry. The ventilatory circuit consists of highfrequency oscillatory ventilator 3100A with patient circuit and model of the lungs realized by a set of rigid demijohns. Transfer of the ventilatory pressure was measured in different compartments of the model for inspirium to expirium ratio 1:1 and 1:2. Other ventilatory parameters were held constant during the experiment.
Název v anglickém jazyce
Distribution of the ventilatory pressure in high-frequency oscillatory ventilation in the anatomically based model of the respiratory system
Popis výsledku anglicky
Amplitude of the pressure oscillations during high-frequency oscillatory ventilation is studied in the model of the respiratory system with five compartments based on the lung morphometry. The ventilatory circuit consists of highfrequency oscillatory ventilator 3100A with patient circuit and model of the lungs realized by a set of rigid demijohns. Transfer of the ventilatory pressure was measured in different compartments of the model for inspirium to expirium ratio 1:1 and 1:2. Other ventilatory parameters were held constant during the experiment.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
48th DGBMT Annual Conference Proceedings
ISBN
—
ISSN
0013-5585
e-ISSN
—
Počet stran výsledku
3
Strana od-do
"S998"-"S1000"
Název nakladatele
Walter de Gruyter GmbH & Co. KG
Místo vydání
Berlin
Místo konání akce
Hannover
Datum konání akce
8. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—