Multi-Step Learning-by-Examples Strategy for Real-Time Brain Stroke Microwave Scattering Data Inversion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F21%3A00345170" target="_blank" >RIV/68407700:21460/21:00345170 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/electronics10010095" target="_blank" >https://doi.org/10.3390/electronics10010095</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/electronics10010095" target="_blank" >10.3390/electronics10010095</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multi-Step Learning-by-Examples Strategy for Real-Time Brain Stroke Microwave Scattering Data Inversion
Popis výsledku v původním jazyce
This work deals with the computationally-efficient inversion of microwave scattering data for brain stroke detection and monitoring. The proposed multi-step approach is based on the Learning-by-Examples (LBE) paradigm and naturally matches the stages and time constraints of an effective clinical diagnosis. Stroke detection, identification, and localization are solved with real-time performance through support vector machines (SVMs) operating both in binary/multiclass classification and in regression modalities. Experimental results dealing with the inversion of laboratory-controlled data are shown to verify the effectiveness of the proposed multi-step LBE methodology and prove its suitability as a viable alternative/support to standard medical diagnostic methods.
Název v anglickém jazyce
Multi-Step Learning-by-Examples Strategy for Real-Time Brain Stroke Microwave Scattering Data Inversion
Popis výsledku anglicky
This work deals with the computationally-efficient inversion of microwave scattering data for brain stroke detection and monitoring. The proposed multi-step approach is based on the Learning-by-Examples (LBE) paradigm and naturally matches the stages and time constraints of an effective clinical diagnosis. Stroke detection, identification, and localization are solved with real-time performance through support vector machines (SVMs) operating both in binary/multiclass classification and in regression modalities. Experimental results dealing with the inversion of laboratory-controlled data are shown to verify the effectiveness of the proposed multi-step LBE methodology and prove its suitability as a viable alternative/support to standard medical diagnostic methods.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LTC19031" target="_blank" >LTC19031: Vývoj metamateriálových aplikátorů pro regionální hypertermický systém a hodnocení přesnosti algoritmů plánování léčby</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electronics
ISSN
2079-9292
e-ISSN
2079-9292
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
17
Strana od-do
1-17
Kód UT WoS článku
000605924600001
EID výsledku v databázi Scopus
2-s2.0-85099424523