Vibrobase Insulation of a Building Excited by the Technical Seismicity Effect of Tube Railway Operation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F11%3A00191759" target="_blank" >RIV/68407700:21610/11:00191759 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Vibrobase Insulation of a Building Excited by the Technical Seismicity Effect of Tube Railway Operation
Popis výsledku v původním jazyce
This paper deals with the application of an elastic elastomer layer at foundation base level in order to eliminate excessive vibrations propagating to the assessed building through the geological environment from an underground railway station structure.The dominant vibrations propagate as non-stationary vibrations through the subsoil from the tube structure in the close vicinity of the analysed building structure. For response analysis, the measured time histories in the construction area were selected and then the typical response was used as an input for a dynamic analysis of the structure. The solution of vibration transfer from the subsoil to the structure is demonstrated using the example of a multi-storey reinforced concrete building, founded on a dual foundation plate. An anti-vibration layer of rubber has been designed between the two plates.
Název v anglickém jazyce
Vibrobase Insulation of a Building Excited by the Technical Seismicity Effect of Tube Railway Operation
Popis výsledku anglicky
This paper deals with the application of an elastic elastomer layer at foundation base level in order to eliminate excessive vibrations propagating to the assessed building through the geological environment from an underground railway station structure.The dominant vibrations propagate as non-stationary vibrations through the subsoil from the tube structure in the close vicinity of the analysed building structure. For response analysis, the measured time histories in the construction area were selected and then the typical response was used as an input for a dynamic analysis of the structure. The solution of vibration transfer from the subsoil to the structure is demonstrated using the example of a multi-storey reinforced concrete building, founded on a dual foundation plate. An anti-vibration layer of rubber has been designed between the two plates.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F11%2F1580" target="_blank" >GAP105/11/1580: Přechodová odezva konstrukcí při krátkodobém dynamickém nebo rázovém zatížení od seismických účinků a výbuchů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Earthquake Resistant Engineering Structures VIII
ISBN
978-1-84564-548-9
ISSN
1746-4498
e-ISSN
—
Počet stran výsledku
10
Strana od-do
79-88
Název nakladatele
WIT Press
Místo vydání
Boston
Místo konání akce
Chianciano Terme
Datum konání akce
7. 9. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—