Analysis of Vibro-based Isolated Building
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F12%3A00201521" target="_blank" >RIV/68407700:21610/12:00201521 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of Vibro-based Isolated Building
Popis výsledku v původním jazyce
The paper deals with the application of an elastic antivibration layer at foundation base level in order to eliminate excessive vibrations propagating to the building through the subsoil from an underground railway structure. The principle of double RC plates with embedded elastomer/rubber layer involves consistent separation of the upper part of the structure from the foundation. The layer of elastomer was considered as the elastic subsoil of the Winkler-Pasternak model below the whole area of the upper part of the foundation plate. The nonstationary time history of vibration is used as an excitation of the structure. An assessment of the effectiveness of the sprung system can be based on a comparison between the measured vibrations and the vibrationlevel of the individual storeys for isolated and nonisolated structure. The springing is, consequently, a very efficient instrument for reduce the transfer of vibration.
Název v anglickém jazyce
Analysis of Vibro-based Isolated Building
Popis výsledku anglicky
The paper deals with the application of an elastic antivibration layer at foundation base level in order to eliminate excessive vibrations propagating to the building through the subsoil from an underground railway structure. The principle of double RC plates with embedded elastomer/rubber layer involves consistent separation of the upper part of the structure from the foundation. The layer of elastomer was considered as the elastic subsoil of the Winkler-Pasternak model below the whole area of the upper part of the foundation plate. The nonstationary time history of vibration is used as an excitation of the structure. An assessment of the effectiveness of the sprung system can be based on a comparison between the measured vibrations and the vibrationlevel of the individual storeys for isolated and nonisolated structure. The springing is, consequently, a very efficient instrument for reduce the transfer of vibration.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F11%2F1580" target="_blank" >GAP105/11/1580: Přechodová odezva konstrukcí při krátkodobém dynamickém nebo rázovém zatížení od seismických účinků a výbuchů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 6th European Congress on Computational Methods in Applied Sciences and Engineering
ISBN
978-3-9503537-0-9
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
Vienna University of Technology
Místo vydání
Vienna
Místo konání akce
Vídeň
Datum konání akce
10. 9. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce