Název v původním jazyce
Detection of fast neutrons with Medipix2 pixel detector
Popis výsledku v původním jazyce
In the past, the Medipix-2 imaging detector was successfully adapted for thermal neutron imaging by our group by adding a 6LiF neutron converter covering the surface of the active part of the detector. Recently, the Medipix-2 detector was also adapted and used for fast neutron imaging. Fast neutrons are detected through proton recoil from a 1 mm thick polyethylene layer placed on the detector surface. Basic detection and imaging properties of the detector were calculated, simulated and measured. The measurements were done using an AmBe neutron source, as well as external neutron beams of the Sparrow reactor at the Czech Technical University in Prague and of the high-flux reactor at the Institut Laue-Langevin (ILL) in Grenoble. The detector provided a reasonable signal-to-background ratio of about eight at the neutron beam of ILL's Neutrograph neutron radiography and tomography station.
Název v anglickém jazyce
Detection of fast neutrons with Medipix2 pixel detector
Popis výsledku anglicky
In the past, the Medipix-2 imaging detector was successfully adapted for thermal neutron imaging by our group by adding a 6LiF neutron converter covering the surface of the active part of the detector. Recently, the Medipix-2 detector was also adapted and used for fast neutron imaging. Fast neutrons are detected through proton recoil from a 1 mm thick polyethylene layer placed on the detector surface. Basic detection and imaging properties of the detector were calculated, simulated and measured. The measurements were done using an AmBe neutron source, as well as external neutron beams of the Sparrow reactor at the Czech Technical University in Prague and of the high-flux reactor at the Institut Laue-Langevin (ILL) in Grenoble. The detector provided a reasonable signal-to-background ratio of about eight at the neutron beam of ILL's Neutrograph neutron radiography and tomography station.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
2008
Číslo periodika v rámci svazku
591
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000257529300017
EID výsledku v databázi Scopus
—