Prostorové rozlišení pixelového detektoru Medipix-2 využitého pro detekci neutronů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F05%3A00031630" target="_blank" >RIV/68378297:_____/05:00031630 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/26722445:_____/05:#0000400
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spatial Resolution of the Medipix-2 as Neutron Pixel Detector
Popis výsledku v původním jazyce
Nowadays promising digital detector systems such as Medipix are available and make possible real-time imaging with high sensitivity and broad dynamic range. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted in the layer into secondary radiation which can be subsequently detected by the pixel detector. The Medipix-2 device was tested as a neutron detector with different types of converters using a collimated beam of thermalneutrons. Converter materials were examined with aim to reach maximal spatial resolution at reasonable detection efficiency. Several images of real objects demonstrating the capabilities have been examined. The performance of the imager was compared with several types of contemporary neutron imaging systems. The results demonstrate superior properties of the Medipix-2 based neutron imager in terms of spatial resolution, linearity and dynamic range
Název v anglickém jazyce
Spatial Resolution of the Medipix-2 as Neutron Pixel Detector
Popis výsledku anglicky
Nowadays promising digital detector systems such as Medipix are available and make possible real-time imaging with high sensitivity and broad dynamic range. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted in the layer into secondary radiation which can be subsequently detected by the pixel detector. The Medipix-2 device was tested as a neutron detector with different types of converters using a collimated beam of thermalneutrons. Converter materials were examined with aim to reach maximal spatial resolution at reasonable detection efficiency. Several images of real objects demonstrating the capabilities have been examined. The performance of the imager was compared with several types of contemporary neutron imaging systems. The results demonstrate superior properties of the Medipix-2 based neutron imager in terms of spatial resolution, linearity and dynamic range
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research. A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
546
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
164-169