Prostorové rozlišení pixelového detektoru Medipix-2 využitého pro detekci neutronů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378297%3A_____%2F04%3A00106138" target="_blank" >RIV/68378297:_____/04:00106138 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spatial Resolution of the Medipix-2 as Neutron Pixel Detector
Popis výsledku v původním jazyce
Nowadays promising digital detector systems such as Medipix are available and make possible real-time imaging with high sensitivity and broad dynamic range. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted in the layer into secondary radiation which can be subsequently detected by the pixel detector. The Medipix-2 device was tested as a neutron detector with different types of converters using a collimated beam of thermalneutrons. Converter materials were examined with aim to reach maximal spatial resolution at reasonable detection efficiency. Several images of real objects demonstrating the capabilities have been examined. The performance of the imager was compared with several types of contemporary neutron imaging systems. The results demonstrate superior properties of the Medipix-2 based neutron imager in terms of spatial resolution, linearity and dynamic range
Název v anglickém jazyce
Spatial Resolution of the Medipix-2 as Neutron Pixel Detector
Popis výsledku anglicky
Nowadays promising digital detector systems such as Medipix are available and make possible real-time imaging with high sensitivity and broad dynamic range. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted in the layer into secondary radiation which can be subsequently detected by the pixel detector. The Medipix-2 device was tested as a neutron detector with different types of converters using a collimated beam of thermalneutrons. Converter materials were examined with aim to reach maximal spatial resolution at reasonable detection efficiency. Several images of real objects demonstrating the capabilities have been examined. The performance of the imager was compared with several types of contemporary neutron imaging systems. The results demonstrate superior properties of the Medipix-2 based neutron imager in terms of spatial resolution, linearity and dynamic range
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Abstracts of the 6th International Workshop on Radiation Imaging Detectors
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
1
Název nakladatele
Glasgow University
Místo vydání
Glasgow, Scotland
Místo konání akce
Glasgow, Scotland
Datum konání akce
25. 7. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—