Monte Carlo simulation-based analysis of unobtrusive PPG monitoring through clothes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21730%2F23%3A00374384" target="_blank" >RIV/68407700:21730/23:00374384 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/CBMS58004.2023.00318" target="_blank" >http://dx.doi.org/10.1109/CBMS58004.2023.00318</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CBMS58004.2023.00318" target="_blank" >10.1109/CBMS58004.2023.00318</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monte Carlo simulation-based analysis of unobtrusive PPG monitoring through clothes
Popis výsledku v původním jazyce
The unobtrusive monitoring of vital parameters has recently gained significant importance in home care and the automotive industry to supervise the driver's awareness. In wearable devices, contact-based photoplethysmography (PPG) enables the estimation of heart rate, respiratory rate, blood pressure, and peripheral arterial oxygen saturation through the optical acquisition of blood volume variations in the skin. This work analyzes the feasibility of unobtrusive acquisition of the PPG signal through clothing using Monte Carlo simulations. For that, we suggest a male and a female model of the human back skin covered with six interchangeable clothing items with different tissue, color, and thickness. The arterial pulsation is simulated through blood volume variation in a modeled vessel during systole, diastole, and end-diastole. The absorption coefficients of each clothing were measured with an optical power meter and modelled accordingly. Nine increasing distances of 0 to 2.95 cm between a red (760 nm) or infra-red (900 nm) Light Emitting Diode (LED) and a photodiode (PD) are investigated. The quality of the PPG signal is evaluated by considering the detected light power, the order of the detected light intensities at systole, diastole and end-diastole, and the perfusion index. The simulations revealed that the ability to detect the PPG pulse through clothing depends on the thickness and type of fabric used, the LED-PD distance of the sensor, and its wavelength. The optimal LED-PD distance was found to be 1.2 to 1.8 cm. The infrared LED generally generates reproducible and better quality PPG signals for cotton and polyamide T-shirts, but not for a thick gray cotton hoodie and a thin acrylic red sweater. Besides, significant differences are reported between the male and the female models. Our results evidence the limitations of PPG monitoring through clothes and suppose a step forward in unobtrusive sensors' design for hospitals and smart cars.
Název v anglickém jazyce
Monte Carlo simulation-based analysis of unobtrusive PPG monitoring through clothes
Popis výsledku anglicky
The unobtrusive monitoring of vital parameters has recently gained significant importance in home care and the automotive industry to supervise the driver's awareness. In wearable devices, contact-based photoplethysmography (PPG) enables the estimation of heart rate, respiratory rate, blood pressure, and peripheral arterial oxygen saturation through the optical acquisition of blood volume variations in the skin. This work analyzes the feasibility of unobtrusive acquisition of the PPG signal through clothing using Monte Carlo simulations. For that, we suggest a male and a female model of the human back skin covered with six interchangeable clothing items with different tissue, color, and thickness. The arterial pulsation is simulated through blood volume variation in a modeled vessel during systole, diastole, and end-diastole. The absorption coefficients of each clothing were measured with an optical power meter and modelled accordingly. Nine increasing distances of 0 to 2.95 cm between a red (760 nm) or infra-red (900 nm) Light Emitting Diode (LED) and a photodiode (PD) are investigated. The quality of the PPG signal is evaluated by considering the detected light power, the order of the detected light intensities at systole, diastole and end-diastole, and the perfusion index. The simulations revealed that the ability to detect the PPG pulse through clothing depends on the thickness and type of fabric used, the LED-PD distance of the sensor, and its wavelength. The optimal LED-PD distance was found to be 1.2 to 1.8 cm. The infrared LED generally generates reproducible and better quality PPG signals for cotton and polyamide T-shirts, but not for a thick gray cotton hoodie and a thin acrylic red sweater. Besides, significant differences are reported between the male and the female models. Our results evidence the limitations of PPG monitoring through clothes and suppose a step forward in unobtrusive sensors' design for hospitals and smart cars.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE 36th International Symposium on Computer-Based Medical Systems (CBMS)
ISBN
979-8-3503-1224-9
ISSN
2372-918X
e-ISSN
2372-9198
Počet stran výsledku
6
Strana od-do
776-781
Název nakladatele
IEEE Xplore
Místo vydání
—
Místo konání akce
L'Aquila
Datum konání akce
22. 6. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001037777900137