In situ Determination of Load Bearing Capacity of Soils on the Airfields
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F15%3A00000609" target="_blank" >RIV/75081431:_____/15:00000609 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In situ Determination of Load Bearing Capacity of Soils on the Airfields
Popis výsledku v původním jazyce
The article presents the results of the earth structures? bearing capacity evaluation and objectification for airfields by means of CBR (California Bearing Ratio) parameter. In order to quantify actual terrain conditions, in situ testing methods are advancing against laboratory testing. However, the optimal solution is to combine precise laboratory testing with in situ measurements. A correlation between CBR values and moisture content values of the backfilling soil of runway strips from earth structureof Žilina Airport was made within the frame of author's research activities. The CBR tests were performed on the clayey gravel specimens, which were prepared in the test cylinders used for a Proctor modified test. It has been found that the correlationallows determining of the moisture level to meet requirements of the RWY recommended by Aerodrome Design Manual [1]. The newest results of CBR in situ measurements on the aerodrome earth structures are also presented.
Název v anglickém jazyce
In situ Determination of Load Bearing Capacity of Soils on the Airfields
Popis výsledku anglicky
The article presents the results of the earth structures? bearing capacity evaluation and objectification for airfields by means of CBR (California Bearing Ratio) parameter. In order to quantify actual terrain conditions, in situ testing methods are advancing against laboratory testing. However, the optimal solution is to combine precise laboratory testing with in situ measurements. A correlation between CBR values and moisture content values of the backfilling soil of runway strips from earth structureof Žilina Airport was made within the frame of author's research activities. The CBR tests were performed on the clayey gravel specimens, which were prepared in the test cylinders used for a Proctor modified test. It has been found that the correlationallows determining of the moisture level to meet requirements of the RWY recommended by Aerodrome Design Manual [1]. The newest results of CBR in situ measurements on the aerodrome earth structures are also presented.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Procedia Earth and Planetary Science, vol. 15 : The World Multidisciplinary Earth Sciences Symposium, WMESS 2015
ISBN
—
ISSN
1878-5220
e-ISSN
—
Počet stran výsledku
8
Strana od-do
11-18
Název nakladatele
Elsevier
Místo vydání
Amsterdam
Místo konání akce
Prague
Datum konání akce
7. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000370751200002