Assessment of Selected Interior Flooring Materials on Indoor Air Quality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F16%3A00000816" target="_blank" >RIV/75081431:_____/16:00000816 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1877705816328508" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1877705816328508</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2016.08.621" target="_blank" >10.1016/j.proeng.2016.08.621</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of Selected Interior Flooring Materials on Indoor Air Quality
Popis výsledku v původním jazyce
Indoor air quality depends on many factors, such as temperature, humidity, odours or presence of pollutants. A lot of materials used in the buildings, either as structural materials or as furnishings, are mostly the indoor air pollution sources. Interior surface materials are generally accepted as the main TVOCs emissions source. The chemical and sensory assessment of selected interior flooring materials on indoor air quality is presented within the paper. Air acceptability, odour intensity and TVOCs concentration for selected interior flooring materials (polyvinyl chloride flooring, tongue flooring and acrylic based flooring) were tested. The chemical and sensory measurements were performed in a glass test chamber. The parameters were monitored by different air change rate per hour. Chemical measurement is based on the absorbed TVOCs gas chromatography analysis. The panellists of sensory assessment consist of group of responsible persons from 20 to 38 years (35% smokers).
Název v anglickém jazyce
Assessment of Selected Interior Flooring Materials on Indoor Air Quality
Popis výsledku anglicky
Indoor air quality depends on many factors, such as temperature, humidity, odours or presence of pollutants. A lot of materials used in the buildings, either as structural materials or as furnishings, are mostly the indoor air pollution sources. Interior surface materials are generally accepted as the main TVOCs emissions source. The chemical and sensory assessment of selected interior flooring materials on indoor air quality is presented within the paper. Air acceptability, odour intensity and TVOCs concentration for selected interior flooring materials (polyvinyl chloride flooring, tongue flooring and acrylic based flooring) were tested. The chemical and sensory measurements were performed in a glass test chamber. The parameters were monitored by different air change rate per hour. Chemical measurement is based on the absorbed TVOCs gas chromatography analysis. The panellists of sensory assessment consist of group of responsible persons from 20 to 38 years (35% smokers).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Procedia Engineering
ISBN
—
ISSN
1877-7058
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1527-1531
Název nakladatele
Elsevier BV
Místo vydání
Netherlands
Místo konání akce
Praha
Datum konání akce
13. 6. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—