Flooring materials impacts on indoor air quality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F17%3A00001180" target="_blank" >RIV/75081431:_____/17:00001180 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flooring materials impacts on indoor air quality
Popis výsledku v původním jazyce
A major pollutant in indoor air are volatile organic compounds (VOCs) emitted from materials and building products The indoor surface materials are considered to be studied as the principal sources of indoor air pollution. The source control is the most practical approach to improve the indoor air quality. The measure for indoor pollution's decreasing seems to be the effective control of volatile organic compounds and indoor odors. The perceived indoor air quality in four rooms with various flooring materials was studied. An untrained sensory panel of 20 subjects assessed perceived air quality in regarding acceptability of the air (from -1 clearly unacceptable to +1 clearly acceptable). Continuously the impact of used flooring materials on VOCs emissions was observed. An electronic nose based on gas chromatography was used for tha analysis of individual VOCs and a photoionization detector with a UV lamp was used for the determination of total volatile organic compounds (TVOC) concentration. The effect of air charge level to TVOC concentrations was studied.
Název v anglickém jazyce
Flooring materials impacts on indoor air quality
Popis výsledku anglicky
A major pollutant in indoor air are volatile organic compounds (VOCs) emitted from materials and building products The indoor surface materials are considered to be studied as the principal sources of indoor air pollution. The source control is the most practical approach to improve the indoor air quality. The measure for indoor pollution's decreasing seems to be the effective control of volatile organic compounds and indoor odors. The perceived indoor air quality in four rooms with various flooring materials was studied. An untrained sensory panel of 20 subjects assessed perceived air quality in regarding acceptability of the air (from -1 clearly unacceptable to +1 clearly acceptable). Continuously the impact of used flooring materials on VOCs emissions was observed. An electronic nose based on gas chromatography was used for tha analysis of individual VOCs and a photoionization detector with a UV lamp was used for the determination of total volatile organic compounds (TVOC) concentration. The effect of air charge level to TVOC concentrations was studied.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th International Multidisciplinary Scientific GeoConference, SGEM 2017
ISBN
9786197408133
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
6
Strana od-do
609-614
Název nakladatele
Stef92 Technology Ltd.
Místo vydání
Sofia (Bulharsko)
Místo konání akce
Albena (Bulharsko)
Datum konání akce
29. 6. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce