Response of current area dosemeters to new operational quantities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F22%3AN0000003" target="_blank" >RIV/86652052:_____/22:N0000003 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/198/17/1313/6655631" target="_blank" >https://academic.oup.com/rpd/article/198/17/1313/6655631</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac154" target="_blank" >10.1093/rpd/ncac154</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Response of current area dosemeters to new operational quantities
Popis výsledku v původním jazyce
New operational quantities for external radiation exposure presented by the ICRU brought changes, which can affect the use of current dosemeters. Dosemeters calibrated in the old quantities should be tested, and the results obtained should be analysed with respect to the new quantities. The difference between the old and new quantities depends primarily on photon energy. This work concerns instruments for area monitoring, which were exposed to reference photon and neutron spectra of mean energies from 65 to 1250 keV and from 0.02 to 10 MeV, respectively. As expected, it was revealed that the current photon dosemeters overestimate the new quantity ambient dose. For the measurements within the energy interval chosen, it seems to be acceptable to implement a correction factor to optimize the response. For the purposes of measurements of photons of lower energies, further research would be needed. To adapt the response of the neutron dosemeter tested, recalibration or redesign can be considered, but no fundamental changes seem to be necessary for the investigated spectra.
Název v anglickém jazyce
Response of current area dosemeters to new operational quantities
Popis výsledku anglicky
New operational quantities for external radiation exposure presented by the ICRU brought changes, which can affect the use of current dosemeters. Dosemeters calibrated in the old quantities should be tested, and the results obtained should be analysed with respect to the new quantities. The difference between the old and new quantities depends primarily on photon energy. This work concerns instruments for area monitoring, which were exposed to reference photon and neutron spectra of mean energies from 65 to 1250 keV and from 0.02 to 10 MeV, respectively. As expected, it was revealed that the current photon dosemeters overestimate the new quantity ambient dose. For the measurements within the energy interval chosen, it seems to be acceptable to implement a correction factor to optimize the response. For the purposes of measurements of photons of lower energies, further research would be needed. To adapt the response of the neutron dosemeter tested, recalibration or redesign can be considered, but no fundamental changes seem to be necessary for the investigated spectra.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20192022156" target="_blank" >VI20192022156: Dozimetrie pro radiační nehody a incidenty v kontextu nových operačních veličin pro externí záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
198
Číslo periodika v rámci svazku
17
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
1313-1321
Kód UT WoS článku
000835887000001