Response of current dosemeters to new operational quantities in rotational geometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F23%3AN0000006" target="_blank" >RIV/86652052:_____/23:N0000006 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/199/15-16/1785/7306607" target="_blank" >https://academic.oup.com/rpd/article/199/15-16/1785/7306607</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac281" target="_blank" >10.1093/rpd/ncac281</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Response of current dosemeters to new operational quantities in rotational geometry
Popis výsledku v původním jazyce
Recently, the ICRU released Report 95, where new operational quantities for external radiation exposure are defined. The new quantities are defined in close relation to the protection quantities. This change affects the practice use of dosemeters. That is why the instruments must be adapted to the measurement of new quantities before their implementing as legally binding. The discrepancies depend on radiation spectra- particle type, energy of particles and direction of incidence. To analyse the performance of currently used instruments, irradiations in photon and neutron fields of various energies were performed for personal and area dosemeters. In this work, the response of photon and neutron personal dosemeters in conditions of rotational geometry is presented. The difference between the responses with respect to the new or old operational quantity was not large, which corresponded to the similar reference values for this irradiation geometry. The mutual ratio depended on the specific radiation quality and geometry. The behaviour of different types of dosemeters varied too.
Název v anglickém jazyce
Response of current dosemeters to new operational quantities in rotational geometry
Popis výsledku anglicky
Recently, the ICRU released Report 95, where new operational quantities for external radiation exposure are defined. The new quantities are defined in close relation to the protection quantities. This change affects the practice use of dosemeters. That is why the instruments must be adapted to the measurement of new quantities before their implementing as legally binding. The discrepancies depend on radiation spectra- particle type, energy of particles and direction of incidence. To analyse the performance of currently used instruments, irradiations in photon and neutron fields of various energies were performed for personal and area dosemeters. In this work, the response of photon and neutron personal dosemeters in conditions of rotational geometry is presented. The difference between the responses with respect to the new or old operational quantity was not large, which corresponded to the similar reference values for this irradiation geometry. The mutual ratio depended on the specific radiation quality and geometry. The behaviour of different types of dosemeters varied too.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20192022156" target="_blank" >VI20192022156: Dozimetrie pro radiační nehody a incidenty v kontextu nových operačních veličin pro externí záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
199
Číslo periodika v rámci svazku
15-16
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
1785-1789
Kód UT WoS článku
001082650600027
EID výsledku v databázi Scopus
2-s2.0-85175006587