Raman spectroscopy at different excitation wavelengths (1064, 785 and 532 nm) as a tool for diagnosis of colon cancer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10284630" target="_blank" >RIV/00216208:11110/14:10284630 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/14:10284630 RIV/60461373:22340/14:43897261
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jrs.4581" target="_blank" >http://dx.doi.org/10.1002/jrs.4581</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jrs.4581" target="_blank" >10.1002/jrs.4581</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Raman spectroscopy at different excitation wavelengths (1064, 785 and 532 nm) as a tool for diagnosis of colon cancer
Popis výsledku v původním jazyce
Raman spectroscopy is structure sensitive non-destructive method that allows observing the status of biological tissues with minimal impact. This method has a great potential in the diagnosis of various types of degenerative diseases including cancer damages. Near-infrared Fourier transform (NIR-FT)-Raman ((ex) similar to 1064nm), NIR-visible (Vis)-Raman ((ex) similar to 785nm) and Vis-Raman ((ex) similar to 532nm) spectra of normal and colorectal carcinoma colon tissue samples were recorded in macroscopic mode at 10-20 randomly chosen independent sites. In the cases of NIR-Vis- and Vis-Raman spectra, enhanced resonance effects were observed for tissue chromophores absorbing in the visible area. Evident spectral differences were noticed for Raman spectra of normal colon tissue samples in comparison with abnormal samples. The average Raman spectra of colon tissue samples were analysed by principal component analysis (PCA) to discriminate normal and abnormal tissues. PCA of combined data
Název v anglickém jazyce
Raman spectroscopy at different excitation wavelengths (1064, 785 and 532 nm) as a tool for diagnosis of colon cancer
Popis výsledku anglicky
Raman spectroscopy is structure sensitive non-destructive method that allows observing the status of biological tissues with minimal impact. This method has a great potential in the diagnosis of various types of degenerative diseases including cancer damages. Near-infrared Fourier transform (NIR-FT)-Raman ((ex) similar to 1064nm), NIR-visible (Vis)-Raman ((ex) similar to 785nm) and Vis-Raman ((ex) similar to 532nm) spectra of normal and colorectal carcinoma colon tissue samples were recorded in macroscopic mode at 10-20 randomly chosen independent sites. In the cases of NIR-Vis- and Vis-Raman spectra, enhanced resonance effects were observed for tissue chromophores absorbing in the visible area. Evident spectral differences were noticed for Raman spectra of normal colon tissue samples in comparison with abnormal samples. The average Raman spectra of colon tissue samples were analysed by principal component analysis (PCA) to discriminate normal and abnormal tissues. PCA of combined data
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FJ - Chirurgie včetně transplantologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13259" target="_blank" >NT13259: Význam vyšetřování plasmatických hladin angiogenetických a imunosupresivních faktorů TGF beta1, VEGF a imunitních buněk uplatňujících se v protinádorové odpovědi (NK, CD8) u pacientů s karcinomem tlustého střeva.</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Raman Spectroscopy
ISSN
0377-0486
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
903-911
Kód UT WoS článku
000343762300008
EID výsledku v databázi Scopus
—