Development of micellar electrokinetic chromatography method for the determination of three defined impurities in indomethacin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F18%3A10382324" target="_blank" >RIV/00216208:11160/18:10382324 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/elps.201800080" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/elps.201800080</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201800080" target="_blank" >10.1002/elps.201800080</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of micellar electrokinetic chromatography method for the determination of three defined impurities in indomethacin
Popis výsledku v původním jazyce
A micellar electrokinetic chromatography method for the determination of indomethacin impurities (4-chlorobenzoic acid, 5-methoxy-2-methyl-3-indoleacetic acid, and 3,4-dichloroindomethacin) has been developed. A 64.5/56-cm fused silica 50 mu m id capillary with extended light path (150 mu m id) detection window was used. Internal standard was 1-naphthylacetic acid. The analytes were separated at 30 kV with DAD detection at 224 nm. A central composite face-centered design was applied for the optimization of the separation conditions. The effect of SDS concentration, content of methanol, concentration of phosphate buffer, and pH of the buffer were studied at three levels. The optimized background electrolyte was 20 mmol/L phosphate buffer (pH 7.57) containing 58 mmol/L SDS and 0% MeOH. Sufficient resolution of all compounds with Rs >= 3.5 was achieved within 10 min. The method was validated for a range of 1.25-80 mu g/mL of each impurity corresponding to 0.05-3.2% relative to the concentration of indomethacin (2.5 mg/mL). The calibration curves were rectilinear with correlation coefficients r(2) exceeding 0.9994. The lower limit of quantification was 0.05% or 1.25 mu g/mL that complies with the reporting limits regarding the ICH Q3A guideline. The method was applied to purity assay of indomethacin in both bulk drug and gel.
Název v anglickém jazyce
Development of micellar electrokinetic chromatography method for the determination of three defined impurities in indomethacin
Popis výsledku anglicky
A micellar electrokinetic chromatography method for the determination of indomethacin impurities (4-chlorobenzoic acid, 5-methoxy-2-methyl-3-indoleacetic acid, and 3,4-dichloroindomethacin) has been developed. A 64.5/56-cm fused silica 50 mu m id capillary with extended light path (150 mu m id) detection window was used. Internal standard was 1-naphthylacetic acid. The analytes were separated at 30 kV with DAD detection at 224 nm. A central composite face-centered design was applied for the optimization of the separation conditions. The effect of SDS concentration, content of methanol, concentration of phosphate buffer, and pH of the buffer were studied at three levels. The optimized background electrolyte was 20 mmol/L phosphate buffer (pH 7.57) containing 58 mmol/L SDS and 0% MeOH. Sufficient resolution of all compounds with Rs >= 3.5 was achieved within 10 min. The method was validated for a range of 1.25-80 mu g/mL of each impurity corresponding to 0.05-3.2% relative to the concentration of indomethacin (2.5 mg/mL). The calibration curves were rectilinear with correlation coefficients r(2) exceeding 0.9994. The lower limit of quantification was 0.05% or 1.25 mu g/mL that complies with the reporting limits regarding the ICH Q3A guideline. The method was applied to purity assay of indomethacin in both bulk drug and gel.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000465" target="_blank" >EF15_003/0000465: Vytvoření expertního týmu pro pokročilý výzkum v separačních vědách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
39
Číslo periodika v rámci svazku
20
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
2550-2557
Kód UT WoS článku
000447441600007
EID výsledku v databázi Scopus
2-s2.0-85054766982