Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10318274" target="_blank" >RIV/00216208:11310/16:10318274 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-015-1583-8" target="_blank" >http://dx.doi.org/10.1007/s00706-015-1583-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-015-1583-8" target="_blank" >10.1007/s00706-015-1583-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes
Popis výsledku v původním jazyce
An array of carbon composite electrodes embedded in a 96-well microtitration plate was applied to differential pulse voltammetry determination of standards of tumor biomarkers 2-(4-hydroxy-3-methoxy-phenyl) acetic acid (homovanillic acid, HVA) and (RS)-hydroxy(4-hydroxy-3-methoxy-phenyl) acetic acid (vanillylmandelic acid, VMA). For the preparation of composite electrodes, graphitic conductive microparticles and nonconductive polystyrene binder were used. For the measurement, a buffer of pH 2 was selected as the optimum medium for both analytes. In this medium, concentration dependences of stand-alone standards were measured; calculated quantification limits were 0.3 A mu mol dm(-3) for HVA and 0.8 A mu mol dm(-3) for VMA. Sorption of analytes on employed working electrode was examined in order to verify, whether the current is influenced by the time period between cell filling and measurement. The sorption was not observed and the current was stable even after 10 min. Developed method
Název v anglickém jazyce
Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes
Popis výsledku anglicky
An array of carbon composite electrodes embedded in a 96-well microtitration plate was applied to differential pulse voltammetry determination of standards of tumor biomarkers 2-(4-hydroxy-3-methoxy-phenyl) acetic acid (homovanillic acid, HVA) and (RS)-hydroxy(4-hydroxy-3-methoxy-phenyl) acetic acid (vanillylmandelic acid, VMA). For the preparation of composite electrodes, graphitic conductive microparticles and nonconductive polystyrene binder were used. For the measurement, a buffer of pH 2 was selected as the optimum medium for both analytes. In this medium, concentration dependences of stand-alone standards were measured; calculated quantification limits were 0.3 A mu mol dm(-3) for HVA and 0.8 A mu mol dm(-3) for VMA. Sorption of analytes on employed working electrode was examined in order to verify, whether the current is influenced by the time period between cell filling and measurement. The sorption was not observed and the current was stable even after 10 min. Developed method
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
147
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
8
Strana od-do
89-96
Kód UT WoS článku
000367521400012