CEval: All-in-one software for data processing and statistical evaluations in affinity capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10325134" target="_blank" >RIV/00216208:11310/16:10325134 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2016.04.004" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2016.04.004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2016.04.004" target="_blank" >10.1016/j.chroma.2016.04.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CEval: All-in-one software for data processing and statistical evaluations in affinity capillary electrophoresis
Popis výsledku v původním jazyce
We introduce CEval software (downloadable for free at echmet.natur.cuni.cz) that was developed for quicker and easier electrophoregram evaluation and further data processing in (affinity) capillary electrophoresis. This software allows for automatic peak detection and evaluation of common peak parameters, such as its migration time, area, width etc. Additionally, the software includes a nonlinear regression engine that performs peak fitting with the Haarhoff-van der Linde (HVL) function, including automated initial guess of the HVL function parameters. HVL is a fundamental peak-shape function in electrophoresis, based on which the correct effective mobility of the analyte represented by the peak is evaluated. Effective mobilities of an analyte at various concentrations of a selector can be further stored and plotted in an affinity CE mode. Consequently, the mobility of the free analyte, mu(A), mobility of the analyte-selector complex, mu(AS), and the apparent complexation constant, K', are first guessed automatically from the linearized data plots and subsequently estimated by the means of nonlinear regression. An option that allows two complexation dependencies to be fitted at once is especially convenient for enantioseparations. Statistical processing of these data is also included, which allowed us to: i) express the 95% confidence intervals for the mu(A), mu(AS), and K' least-squares estimates, ii) do hypothesis testing on the estimated parameters for the first time. We demonstrate the benefits of the CEval software by inspecting complexation of tryptophan methyl ester with two cyclodextrins, neutral heptakis(2,6-di-O-methyl)-beta-CD and charged heptakis(6-O-sulfo)-beta-CD.
Název v anglickém jazyce
CEval: All-in-one software for data processing and statistical evaluations in affinity capillary electrophoresis
Popis výsledku anglicky
We introduce CEval software (downloadable for free at echmet.natur.cuni.cz) that was developed for quicker and easier electrophoregram evaluation and further data processing in (affinity) capillary electrophoresis. This software allows for automatic peak detection and evaluation of common peak parameters, such as its migration time, area, width etc. Additionally, the software includes a nonlinear regression engine that performs peak fitting with the Haarhoff-van der Linde (HVL) function, including automated initial guess of the HVL function parameters. HVL is a fundamental peak-shape function in electrophoresis, based on which the correct effective mobility of the analyte represented by the peak is evaluated. Effective mobilities of an analyte at various concentrations of a selector can be further stored and plotted in an affinity CE mode. Consequently, the mobility of the free analyte, mu(A), mobility of the analyte-selector complex, mu(AS), and the apparent complexation constant, K', are first guessed automatically from the linearized data plots and subsequently estimated by the means of nonlinear regression. An option that allows two complexation dependencies to be fitted at once is especially convenient for enantioseparations. Statistical processing of these data is also included, which allowed us to: i) express the 95% confidence intervals for the mu(A), mu(AS), and K' least-squares estimates, ii) do hypothesis testing on the estimated parameters for the first time. We demonstrate the benefits of the CEval software by inspecting complexation of tryptophan methyl ester with two cyclodextrins, neutral heptakis(2,6-di-O-methyl)-beta-CD and charged heptakis(6-O-sulfo)-beta-CD.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1445
Číslo periodika v rámci svazku
1445
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
158-165
Kód UT WoS článku
000375630900019