Long-term stability of cancer biomarkers in human serum: biomarkers of oxidative stress and redox status, homocysteine, CRP and the enzymes ALT and GGT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39899905" target="_blank" >RIV/00216275:25310/15:39899905 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2217/bmm.15.14" target="_blank" >http://dx.doi.org/10.2217/bmm.15.14</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2217/bmm.15.14" target="_blank" >10.2217/bmm.15.14</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long-term stability of cancer biomarkers in human serum: biomarkers of oxidative stress and redox status, homocysteine, CRP and the enzymes ALT and GGT
Popis výsledku v původním jazyce
Aim: Five frequently used biomarkers in cancer research and epidemiological studies were tested for their assay stability upon storage of serum for 12 months at -20 and -70/-80 degrees C. Materials & methods: The biomarker assays include reactive oxygenmetabolites (ROM), the total thiol levels (TTL), homocysteine (HCy), C-reactive protein (HS-CRP) and two liver enzymes, alanine aminotransferase (ALT) and -glutamyltransferase (GGT). Results: The assays for ROM, HCy, HS-CRP and GGT were stable in human serum samples at the two temperatures tested. The two other assays TTL and ALT, however, showed statistically significant differences in their stability between -20 and -80 degrees C. Conclusion: Therefore, storage at -80 degrees C is advised to maintaina reliable assay outcome when serum samples have to be stored for longer periods.
Název v anglickém jazyce
Long-term stability of cancer biomarkers in human serum: biomarkers of oxidative stress and redox status, homocysteine, CRP and the enzymes ALT and GGT
Popis výsledku anglicky
Aim: Five frequently used biomarkers in cancer research and epidemiological studies were tested for their assay stability upon storage of serum for 12 months at -20 and -70/-80 degrees C. Materials & methods: The biomarker assays include reactive oxygenmetabolites (ROM), the total thiol levels (TTL), homocysteine (HCy), C-reactive protein (HS-CRP) and two liver enzymes, alanine aminotransferase (ALT) and -glutamyltransferase (GGT). Results: The assays for ROM, HCy, HS-CRP and GGT were stable in human serum samples at the two temperatures tested. The two other assays TTL and ALT, however, showed statistically significant differences in their stability between -20 and -80 degrees C. Conclusion: Therefore, storage at -80 degrees C is advised to maintaina reliable assay outcome when serum samples have to be stored for longer periods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomarkers in Medicine
ISSN
1752-0363
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
425-432
Kód UT WoS článku
000354647700004
EID výsledku v databázi Scopus
—