Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F25%3A39922832" target="_blank" >RIV/00216275:25310/25:39922832 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.jpba.2025.116831" target="_blank" >https://doi.org/10.1016/j.jpba.2025.116831</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2025.116831" target="_blank" >10.1016/j.jpba.2025.116831</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria
Popis výsledku v původním jazyce
Monitoring patients with phenylketonuria (PKU) requires accurately measuring phenylalanine and tyrosine levels in a small volume of blood samples obtained by the dried blood spot (DBS) technique. The aim was to study selected parameters influencing the quantitative results. Phenylalanine and tyrosine were extracted from DBS samples with methanol, and 5 internal standard introduction techniques were tested. Phenylalanine and tyrosine levels were measured in 6-mm discs punched from DBS, pre-punched 9-mm discs containing the entire DBS sample, and liquid blood by HPLC-MS-MS. Levels in 6-mm discs punched from DBS measured by HPLC-MS/MS were compared with those measured by the HPLC-FLD. The analytical parameters of the method are satisfactory, linearity in the range of 25–1200 μmol/L (LOD, LOQ and LLOQ values 0.2 μmol/L, 0.5 μmol/L and 3.8 μmol/L for phenylalanine, 0.5 μmol/L, 1.5 μmol/L and 5.1 μmol/L for tyrosine), within-run precision 1.8 %–3.7 % for phenylalanine, 1.9 %–2.7 % for tyrosine, between-run precision 4.7 %–5.9 % for phenylalanine, 4.1 %–5.4 % for tyrosine, recovery 93.8 %–100.4 % for phenylalanine and 93.7 %–99.1 % for tyrosine. Good agreement was found between phenylalanine and tyrosine concentrations in 6-mm discs punched from DBS (R = 0.896, p < 0.001, and R = 0.907, p < 0.001, respectively), pre-punched 9-mm discs containing the entire DBS sample (R = 0.960, p < 0.001, and R = 0.950, p < 0.001, respectively) and liquid blood, as well as between phenylalanine and tyrosine concentrations obtained by HPLC-MS/MS and HPLC-FLD (R = 0.968, p < 0.001, and R = 0.984, p < 0.001, respectively). The presented method is suitable for monitoring patients with PKU.
Název v anglickém jazyce
Simultaneous determination of phenylalanine and tyrosine levels in human blood obtained by the dried spot technique for monitoring of patients with phenylketonuria
Popis výsledku anglicky
Monitoring patients with phenylketonuria (PKU) requires accurately measuring phenylalanine and tyrosine levels in a small volume of blood samples obtained by the dried blood spot (DBS) technique. The aim was to study selected parameters influencing the quantitative results. Phenylalanine and tyrosine were extracted from DBS samples with methanol, and 5 internal standard introduction techniques were tested. Phenylalanine and tyrosine levels were measured in 6-mm discs punched from DBS, pre-punched 9-mm discs containing the entire DBS sample, and liquid blood by HPLC-MS-MS. Levels in 6-mm discs punched from DBS measured by HPLC-MS/MS were compared with those measured by the HPLC-FLD. The analytical parameters of the method are satisfactory, linearity in the range of 25–1200 μmol/L (LOD, LOQ and LLOQ values 0.2 μmol/L, 0.5 μmol/L and 3.8 μmol/L for phenylalanine, 0.5 μmol/L, 1.5 μmol/L and 5.1 μmol/L for tyrosine), within-run precision 1.8 %–3.7 % for phenylalanine, 1.9 %–2.7 % for tyrosine, between-run precision 4.7 %–5.9 % for phenylalanine, 4.1 %–5.4 % for tyrosine, recovery 93.8 %–100.4 % for phenylalanine and 93.7 %–99.1 % for tyrosine. Good agreement was found between phenylalanine and tyrosine concentrations in 6-mm discs punched from DBS (R = 0.896, p < 0.001, and R = 0.907, p < 0.001, respectively), pre-punched 9-mm discs containing the entire DBS sample (R = 0.960, p < 0.001, and R = 0.950, p < 0.001, respectively) and liquid blood, as well as between phenylalanine and tyrosine concentrations obtained by HPLC-MS/MS and HPLC-FLD (R = 0.968, p < 0.001, and R = 0.984, p < 0.001, respectively). The presented method is suitable for monitoring patients with PKU.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
1873-264X
Svazek periodika
260
Číslo periodika v rámci svazku
August 2025
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
116831
Kód UT WoS článku
001454117200001
EID výsledku v databázi Scopus
2-s2.0-105000487145