A new approach to measuring the temperature fields in reflow ovens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0197663" target="_blank" >RIV/00216305:26220/26:0197663 - isvavai.cz</a>
Výsledek na webu
<a href="https://sciendo.com/article/10.2478/jee-2025-0019" target="_blank" >https://sciendo.com/article/10.2478/jee-2025-0019</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/jee-2025-0019" target="_blank" >10.2478/jee-2025-0019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A new approach to measuring the temperature fields in reflow ovens
Popis výsledku v původním jazyce
Electronics play an increasingly significant role in our lives. Consequently, the demand for both production volume and quality in electronics is continuously rising. Conveyor reflow ovens are the most widely used technology for soldering electronic assemblies onto printed circuit boards. The implementation of these ovens directly affects the quality of solder joints and, most importantly, the reliability of manufactured electronic assemblies, which are present in virtually all aspects of daily life. The solder joint is formed by the reflow of the solder alloy and is defined by the thermal profile, which represents temperature over time. The most common heating method relies on forced hot air convection, where the printed circuit board with mounted components moves through the oven. One of the key design requirements for these ovens is maintaining a consistent thermal profile to achieve a homogeneous temperature field across the reflow zones. To assess this condition, it is essential to measure convection under operating conditions. A new method for measuring the temperature field directly within the conveyor oven has been developed and experimentally verified during production.
Název v anglickém jazyce
A new approach to measuring the temperature fields in reflow ovens
Popis výsledku anglicky
Electronics play an increasingly significant role in our lives. Consequently, the demand for both production volume and quality in electronics is continuously rising. Conveyor reflow ovens are the most widely used technology for soldering electronic assemblies onto printed circuit boards. The implementation of these ovens directly affects the quality of solder joints and, most importantly, the reliability of manufactured electronic assemblies, which are present in virtually all aspects of daily life. The solder joint is formed by the reflow of the solder alloy and is defined by the thermal profile, which represents temperature over time. The most common heating method relies on forced hot air convection, where the printed circuit board with mounted components moves through the oven. One of the key design requirements for these ovens is maintaining a consistent thermal profile to achieve a homogeneous temperature field across the reflow zones. To assess this condition, it is essential to measure convection under operating conditions. A new method for measuring the temperature field directly within the conveyor oven has been developed and experimentally verified during production.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electrical Engineering-Elektrotechnicky Casopis
ISSN
1335-3632
e-ISSN
1339-309X
Svazek periodika
76
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
6
Strana od-do
184-189
Kód UT WoS článku
001462867000008
EID výsledku v databázi Scopus
2-s2.0-105003634143