Development of Simple Splitless Gradient Liquid Chromatographic system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F12%3APU102164" target="_blank" >RIV/00216305:26310/12:PU102164 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of Simple Splitless Gradient Liquid Chromatographic system
Popis výsledku v původním jazyce
A simple gradient liquid chromatographic system for micro and nano column separations has been assembled and tested. The device involves simple splitless gradient generation and sample delivery. Experimental configuration consists of an OEM programmablesyringe pump equipped with a glass microsyringe and ten-port selector valve. Automated system was controlled via LabVIEW development environment. Continuous gradients of mobile phase were created in the syringe barrel by successive sucking of adequate volumes of four mobile phases with gradually decreasing acetonitrile concentration and due to turbulent mixing occurred at the syringe needle-barrel boundary. System performance was evaluated using test mixture of six alkylphenones. Good values of relativestandard deviation of retention times were received (intra-day RSD < 0.3 %, inter-day RSD < 1.4 %). Repeatability of sample injection in the range 0.1 ? 3 ul was evaluated. The peak areas were measured and statistically evaluated (RSD <
Název v anglickém jazyce
Development of Simple Splitless Gradient Liquid Chromatographic system
Popis výsledku anglicky
A simple gradient liquid chromatographic system for micro and nano column separations has been assembled and tested. The device involves simple splitless gradient generation and sample delivery. Experimental configuration consists of an OEM programmablesyringe pump equipped with a glass microsyringe and ten-port selector valve. Automated system was controlled via LabVIEW development environment. Continuous gradients of mobile phase were created in the syringe barrel by successive sucking of adequate volumes of four mobile phases with gradually decreasing acetonitrile concentration and due to turbulent mixing occurred at the syringe needle-barrel boundary. System performance was evaluated using test mixture of six alkylphenones. Good values of relativestandard deviation of retention times were received (intra-day RSD < 0.3 %, inter-day RSD < 1.4 %). Repeatability of sample injection in the range 0.1 ? 3 ul was evaluated. The peak areas were measured and statistically evaluated (RSD <
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Studentská odborná konference Chemie je život - Sborník příspěvků
ISBN
978-80-214-4644-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
446-449
Název nakladatele
Vysoké učení technické v Brně, Fakulta chemická, Purkyňova 464/118, 612 00 Brno
Místo vydání
Neuveden
Místo konání akce
Brno
Datum konání akce
7. 12. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—