Calibration of stem heat balance sensors upon a study of water balance of the hop plantation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F14864347%3A_____%2F12%3A%230000406" target="_blank" >RIV/14864347:_____/12:#0000406 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.actahort.org/books/951/951_8.htm" target="_blank" >http://www.actahort.org/books/951/951_8.htm</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration of stem heat balance sensors upon a study of water balance of the hop plantation
Popis výsledku v původním jazyce
Evapotranspiration of the Czech hop cultivar Agnus plantation was investigated during three consecutive growing seasons. We measured two components of the water balance: total eva-potranspiration and transpiration of the bines (using the stem heat balance sensors type EMS SF62). Actual evapotranspiration peaked when the crop was fully developed, at 80-90 % of the potential evapotranspiration. To ensure the correctness of the sap flow measurements, calibration of the sap flow sensors was performed. Justbefore the harvest, total of 18 bines were removed from the plants and their water uptake was measures volumetrically. Acuracy of the sap flow measurement was ?3 % when compared against potometry.
Název v anglickém jazyce
Calibration of stem heat balance sensors upon a study of water balance of the hop plantation
Popis výsledku anglicky
Evapotranspiration of the Czech hop cultivar Agnus plantation was investigated during three consecutive growing seasons. We measured two components of the water balance: total eva-potranspiration and transpiration of the bines (using the stem heat balance sensors type EMS SF62). Actual evapotranspiration peaked when the crop was fully developed, at 80-90 % of the potential evapotranspiration. To ensure the correctness of the sap flow measurements, calibration of the sap flow sensors was performed. Justbefore the harvest, total of 18 bines were removed from the plants and their water uptake was measures volumetrically. Acuracy of the sap flow measurement was ?3 % when compared against potometry.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acta Horticulturae
ISBN
9789066053588
ISSN
0567-7572
e-ISSN
—
Počet stran výsledku
8
Strana od-do
79-86
Název nakladatele
International Society of Horticultural Science
Místo vydání
Leuven, Belgie
Místo konání akce
Volterra, Italy
Datum konání akce
8. 5. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—