Calibration of Stem Heat Balance Sensors upon a Study of Water Balance of the Hop Plantation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43410%2F12%3A00190623" target="_blank" >RIV/62156489:43410/12:00190623 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration of Stem Heat Balance Sensors upon a Study of Water Balance of the Hop Plantation
Popis výsledku v původním jazyce
Evapotranspiration of the Czech hop cultivar Agnus (Humulus lupulus L.) plantation was investigated during three consecutive growing seasons. We measured two components of the water balance: total evapotranspiration (using the Bowen ratio energy balancemethod) and transpiration of the bines (using the stem heat balance sensors type EMS SF 62). Actual evapotranspiration peaked when the crop was fully developed, at 80 - 90% of the potential evapotranspiration. Most of the water was evaporated and less than half of the total amount of vaporized water was transpired (the partitioning depended on a stage of crop development). EMS heat balance sensors don't require any empirical calibration. However, to ensure the correctness of the sap flow measurements, acalibration of the sap flow sensors was performed. Just before the harvest, a total of eighteen bines were removed from the plants and their water uptake was measured potometrically (volumetrically). Accuracy of the sap flow measurement
Název v anglickém jazyce
Calibration of Stem Heat Balance Sensors upon a Study of Water Balance of the Hop Plantation
Popis výsledku anglicky
Evapotranspiration of the Czech hop cultivar Agnus (Humulus lupulus L.) plantation was investigated during three consecutive growing seasons. We measured two components of the water balance: total evapotranspiration (using the Bowen ratio energy balancemethod) and transpiration of the bines (using the stem heat balance sensors type EMS SF 62). Actual evapotranspiration peaked when the crop was fully developed, at 80 - 90% of the potential evapotranspiration. Most of the water was evaporated and less than half of the total amount of vaporized water was transpired (the partitioning depended on a stage of crop development). EMS heat balance sensors don't require any empirical calibration. However, to ensure the correctness of the sap flow measurements, acalibration of the sap flow sensors was performed. Just before the harvest, a total of eighteen bines were removed from the plants and their water uptake was measured potometrically (volumetrically). Accuracy of the sap flow measurement
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GK - Lesnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0017" target="_blank" >EE2.3.30.0017: Postdoktorandi v oborech biologických věd na MENDELU</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Horticulturae
ISSN
0567-7572
e-ISSN
—
Svazek periodika
951
Číslo periodika v rámci svazku
June
Stát vydavatele periodika
BE - Belgické království
Počet stran výsledku
8
Strana od-do
79-86
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—