Wrist cuff method determines mean arterial pressure in dual-cuff blood pressure system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F14%3A43923490" target="_blank" >RIV/49777513:23220/14:43923490 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wrist cuff method determines mean arterial pressure in dual-cuff blood pressure system
Popis výsledku v původním jazyce
Mean arterial pressure (MAP) is the pressure in the arteries averaged over time. Oscillometric blood pressure (BP) monitors determine the value of MAP by processing arterial pulses in the cuff. Cuff pressure at the point of largest pulse amplitude is equal to MAP. The oscillometric determination of MAP is subject to errors resulting from wave reflections and stroke volume variability. We developed an experimental system that uses two cuffs in order to improve accuracy of noninvasive BP measurement. Thesystem consists of a compact module with pneumatic and electronic circuits, two detachable cuffs (arm and wrist), and a notebook computer connected to the module via a USB cable. This study concentrated on improvements in the determination of MAP using the wrist cuff pulses. The smallest wrist cuff amplitude in the middle segment of BP test was determined as the point of MAP. The corresponding arm cuff pressure was the value of MAP. Waveforms and cuff pressures from 40 BP tests were used
Název v anglickém jazyce
Wrist cuff method determines mean arterial pressure in dual-cuff blood pressure system
Popis výsledku anglicky
Mean arterial pressure (MAP) is the pressure in the arteries averaged over time. Oscillometric blood pressure (BP) monitors determine the value of MAP by processing arterial pulses in the cuff. Cuff pressure at the point of largest pulse amplitude is equal to MAP. The oscillometric determination of MAP is subject to errors resulting from wave reflections and stroke volume variability. We developed an experimental system that uses two cuffs in order to improve accuracy of noninvasive BP measurement. Thesystem consists of a compact module with pneumatic and electronic circuits, two detachable cuffs (arm and wrist), and a notebook computer connected to the module via a USB cable. This study concentrated on improvements in the determination of MAP using the wrist cuff pulses. The smallest wrist cuff amplitude in the middle segment of BP test was determined as the point of MAP. The corresponding arm cuff pressure was the value of MAP. Waveforms and cuff pressures from 40 BP tests were used
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2014 International Conference on Applied Electronics (APPEL 2014)
ISBN
978-80-261-0276-2
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
145-148
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
9. 9. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—