Determination of systolic, mean and diastolic blood pressures with dual cuff system is based on physiology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F16%3A43929309" target="_blank" >RIV/49777513:23220/16:43929309 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7577254/" target="_blank" >http://ieeexplore.ieee.org/document/7577254/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/AE.2016.7577254" target="_blank" >10.1109/AE.2016.7577254</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of systolic, mean and diastolic blood pressures with dual cuff system is based on physiology
Popis výsledku v původním jazyce
Single cuff automatic blood pressure (BP) measurements are subject to errors because the BP values are based on statistical estimation rather than on physiological principles. We developed a dual cuff experimental system that uses an arm cuff and a wrist cuff. The wrist cuff function is similar to auscultation. This study concentrated on the determination of systolic, diastolic and mean BP using the wrist cuff pulse waveforms and the arm cuff pressures. Fifty two BP tests from our database were used to compute blood pressures using the wrist cuff method and the single arm cuff method and the two methods were compared. Mean BP values for both methods were similar but there were important individual differences. The dual cuff method should prove to be more accurate than single cuff methods because it is based on physiological principles.
Název v anglickém jazyce
Determination of systolic, mean and diastolic blood pressures with dual cuff system is based on physiology
Popis výsledku anglicky
Single cuff automatic blood pressure (BP) measurements are subject to errors because the BP values are based on statistical estimation rather than on physiological principles. We developed a dual cuff experimental system that uses an arm cuff and a wrist cuff. The wrist cuff function is similar to auscultation. This study concentrated on the determination of systolic, diastolic and mean BP using the wrist cuff pulse waveforms and the arm cuff pressures. Fifty two BP tests from our database were used to compute blood pressures using the wrist cuff method and the single arm cuff method and the two methods were compared. Mean BP values for both methods were similar but there were important individual differences. The dual cuff method should prove to be more accurate than single cuff methods because it is based on physiological principles.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference on Applied Electronics (AE 2016) : proceedings
ISBN
978-80-261-0601-2
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
117-120
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
6. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—