Reliability of glued joints on flexible substrates during accelerated current ageing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F19%3A43955605" target="_blank" >RIV/49777513:23220/19:43955605 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8810273" target="_blank" >https://ieeexplore.ieee.org/document/8810273</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISSE.2019.8810273" target="_blank" >10.1109/ISSE.2019.8810273</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reliability of glued joints on flexible substrates during accelerated current ageing
Popis výsledku v původním jazyce
This paper deals with reliability of joints glued by non-conductive adhesives (NCA) on flexible substrates during electrical current ageing. Also the comparison of NCA joints ageing with ECA joints ageing is presented in this paper. Two types of adhesives were used for the experiment – non-conductive UV curable acrylic adhesive Loctite AA3926 (NCA) and electrically conductive two part epoxy adhesive MG 8331S (ECA). The purpose of the experiment was to verify the reliability of NCA joints during the electrical current accelerated ageing. The electrical resistance of UV NCA joints on flexible DuPont Pyralux substrate before, during and after electrical current load was better than resistance of ECA joints and UV NCA can be recommended.
Název v anglickém jazyce
Reliability of glued joints on flexible substrates during accelerated current ageing
Popis výsledku anglicky
This paper deals with reliability of joints glued by non-conductive adhesives (NCA) on flexible substrates during electrical current ageing. Also the comparison of NCA joints ageing with ECA joints ageing is presented in this paper. Two types of adhesives were used for the experiment – non-conductive UV curable acrylic adhesive Loctite AA3926 (NCA) and electrically conductive two part epoxy adhesive MG 8331S (ECA). The purpose of the experiment was to verify the reliability of NCA joints during the electrical current accelerated ageing. The electrical resistance of UV NCA joints on flexible DuPont Pyralux substrate before, during and after electrical current load was better than resistance of ECA joints and UV NCA can be recommended.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2019 42nd International Spring Seminar on Electronics Technology (ISSE 2019) : /proceedings/
ISBN
978-1-7281-1874-1
ISSN
2161-2528
e-ISSN
2161-2536
Počet stran výsledku
7
Strana od-do
1-7
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Wroclaw, Poland
Datum konání akce
15. 5. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000507501000045