Popis výsledku v původním jazyce
This paper deals with the reliability under the flowing mixed gases corrosion test of interconnection techniques for the mounting surface mounted device (SMD) component. In the experiment, three types of substrates (conductive stretchable textile ribbon, knitted fabric, and flexible kapton substrate) and three contacting techniques (low-temperature soldering, isotropic electrically conductive adhesive bonding, and non-conductive adhesive bonding) were used. The experiment provided proof that soldered or non-conductive adhesive bonded samples are applicable even in a contaminated or industrial corrosive atmosphere, and the electrical resistance of joints on these samples remains acceptable. It follows e-textiles with soldered or non- =conductive adhesive bonded components can also be used in a contaminated or industrial atmosphere.
Název v anglickém jazyce
Influence of Corrosive Gases on Reliability of Conductive Joints
Popis výsledku anglicky
This paper deals with the reliability under the flowing mixed gases corrosion test of interconnection techniques for the mounting surface mounted device (SMD) component. In the experiment, three types of substrates (conductive stretchable textile ribbon, knitted fabric, and flexible kapton substrate) and three contacting techniques (low-temperature soldering, isotropic electrically conductive adhesive bonding, and non-conductive adhesive bonding) were used. The experiment provided proof that soldered or non-conductive adhesive bonded samples are applicable even in a contaminated or industrial corrosive atmosphere, and the electrical resistance of joints on these samples remains acceptable. It follows e-textiles with soldered or non- =conductive adhesive bonded components can also be used in a contaminated or industrial atmosphere.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2022 International Conference on Diagnostics in Electrical Engineering (Diagnostika) : CDEE 2022
ISBN
978-1-66548-082-6
ISSN
—
e-ISSN
2464-708X
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
University of West Bohemia in Pilsen
Místo vydání
Pilsen
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
6. 9. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—