Iterative Refinement of Hand-Eye Calibration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F18%3A43951703" target="_blank" >RIV/49777513:23520/18:43951703 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8560513&isnumber=8560337" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8560513&isnumber=8560337</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/COASE.2018.8560513" target="_blank" >10.1109/COASE.2018.8560513</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Iterative Refinement of Hand-Eye Calibration
Popis výsledku v původním jazyce
This article describes a new proposed algorithm for an iterative refinement of a hand-eye calibration. The main purpose of this type of calibration is to find the relative position of a flange of a robot and a mounted optical sensor, which is an important task for robotic seam tracking systems. The principle of the hand-eye calibration and chosen algorithms are briefly introduced in the beginning. Afterwards, the calibration procedure with the chosen calibration object and its issues are described. Then the algorithm for calibration improvement is presented, which is based on the iterative elimination of the calibration positions according to the proposed criterion. Finally, the proposed algorithm is tested in simulations and also in a real system.
Název v anglickém jazyce
Iterative Refinement of Hand-Eye Calibration
Popis výsledku anglicky
This article describes a new proposed algorithm for an iterative refinement of a hand-eye calibration. The main purpose of this type of calibration is to find the relative position of a flange of a robot and a mounted optical sensor, which is an important task for robotic seam tracking systems. The principle of the hand-eye calibration and chosen algorithms are briefly introduced in the beginning. Afterwards, the calibration procedure with the chosen calibration object and its issues are described. Then the algorithm for calibration improvement is presented, which is based on the iterative elimination of the calibration positions according to the proposed criterion. Finally, the proposed algorithm is tested in simulations and also in a real system.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20204 - Robotics and automatic control
Návaznosti výsledku
Projekt
<a href="/cs/project/FV10668" target="_blank" >FV10668: Vývoj kognitivního systému pro automatické navádění robota v 7D pro úlohu laserového kalení, svařování, navařování a řezání</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 14th International Conference on Automation Science and Engineering}
ISBN
978-1-5386-3593-3
ISSN
2161-8070
e-ISSN
2161-8089
Počet stran výsledku
6
Strana od-do
457-462
Název nakladatele
IEEE, Inc.
Místo vydání
New York
Místo konání akce
Mnichov, Německo
Datum konání akce
20. 8. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000460536600071