Piezoelectric Immunosensor for the Determination of C-Reactive Protein
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F19%3A00537181" target="_blank" >RIV/60162694:G44__/19:00537181 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.electrochemsci.org/papers/vol14/140908470.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol14/140908470.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.20964/2019.09.02" target="_blank" >10.20964/2019.09.02</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Piezoelectric Immunosensor for the Determination of C-Reactive Protein
Popis výsledku v původním jazyce
C-reactive protein (CRP) is a common biomarker of inflammatory processes and it typically serves for the distinguishing of bacterial and viral diseases. It is typically measured in the blood, plasma or serum by immunoassay like agglutination or enzymatic immunoassays. In this paper, a new immunoassay based on a piezoelectric biosensor was introduced. QCM with basic frequency of oscillations 10 MHz and gold electrodes served as a platform and it was modified with antibodies against CRP and silica nanoparticles. Separately, antibody functionalized silica nanoparticles were prepared and they further served for signal amplification. CRP was assayed with limit of detection equal to 0.080 mg/l. The assay was successfully validated to standard ELISA method and no significant interference by IgM, TNF alpha and albumin was observed. The biosensor-based assay appears to be practically applicable and can serve for routine diagnosis purpose.
Název v anglickém jazyce
Piezoelectric Immunosensor for the Determination of C-Reactive Protein
Popis výsledku anglicky
C-reactive protein (CRP) is a common biomarker of inflammatory processes and it typically serves for the distinguishing of bacterial and viral diseases. It is typically measured in the blood, plasma or serum by immunoassay like agglutination or enzymatic immunoassays. In this paper, a new immunoassay based on a piezoelectric biosensor was introduced. QCM with basic frequency of oscillations 10 MHz and gold electrodes served as a platform and it was modified with antibodies against CRP and silica nanoparticles. Separately, antibody functionalized silica nanoparticles were prepared and they further served for signal amplification. CRP was assayed with limit of detection equal to 0.080 mg/l. The assay was successfully validated to standard ELISA method and no significant interference by IgM, TNF alpha and albumin was observed. The biosensor-based assay appears to be practically applicable and can serve for routine diagnosis purpose.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
1452-3981
Svazek periodika
14
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
9
Strana od-do
8470-8478
Kód UT WoS článku
000483307100010
EID výsledku v databázi Scopus
2-s2.0-85072854723