Dust pollution in university offices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F15%3A67590" target="_blank" >RIV/60460709:41310/15:67590 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dust pollution in university offices
Popis výsledku v původním jazyce
The aim of this paper is to present results of microclimatic research focused mainly on dust pollution in several offices of Departments in the Faculty of Engineering at Czech University of Life Sciences Prague. The attention is paid to the dimensions ofthe room, floor covering, furniture, equipment, ventilation, frequency of the use and period of the year. In the frame of this research the concentration of air dust was measured by special exact instrument Dust-Track aerosol monitor. After the installation of different impactors the PM1, PM2.5, PM4, PM10 size fractions were also measured. The obtained results of measurements were evaluated by the statistical instruments and concentrations of different size of dust particles were analyzed. Results of different indoor conditions were generalized. Based on the results of measurements practical recommendations for the design, use, cleaning and ventilation of these types of rooms and buildings were summarised in the conclusions.
Název v anglickém jazyce
Dust pollution in university offices
Popis výsledku anglicky
The aim of this paper is to present results of microclimatic research focused mainly on dust pollution in several offices of Departments in the Faculty of Engineering at Czech University of Life Sciences Prague. The attention is paid to the dimensions ofthe room, floor covering, furniture, equipment, ventilation, frequency of the use and period of the year. In the frame of this research the concentration of air dust was measured by special exact instrument Dust-Track aerosol monitor. After the installation of different impactors the PM1, PM2.5, PM4, PM10 size fractions were also measured. The obtained results of measurements were evaluated by the statistical instruments and concentrations of different size of dust particles were analyzed. Results of different indoor conditions were generalized. Based on the results of measurements practical recommendations for the design, use, cleaning and ventilation of these types of rooms and buildings were summarised in the conclusions.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
759-764
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—