Dust pollution in buildings for housing of meat chickens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F16%3A70607" target="_blank" >RIV/60460709:41310/16:70607 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dust pollution in buildings for housing of meat chickens
Popis výsledku v původním jazyce
The aim of this paper is to present the results of microclimatic research focused on dust pollution in agricultural buildings used for fattening of chickens. The attention is paid mainly to the construction and influence of the ventilation system. The overall layout of the farm and the ventilation system solutions significantly affect the quality of the indoor climate in terms of dust in the halls for poultry. In the frame of this research the concentration of air dust was measured by exact instrument Dust-Track aerosol monitor. Using the special impactors the PM1, PM2.5, PM4, PM10 size fractions were also measured. The obtained results of measurements were evaluated and concentrations of different size of dust particles were analyzed. Results of different indoor conditions were generalized. Based on the results of the measurements practical recommendations for the design, use and ventilation of these types of buildings were summarized in the conclusions.
Název v anglickém jazyce
Dust pollution in buildings for housing of meat chickens
Popis výsledku anglicky
The aim of this paper is to present the results of microclimatic research focused on dust pollution in agricultural buildings used for fattening of chickens. The attention is paid mainly to the construction and influence of the ventilation system. The overall layout of the farm and the ventilation system solutions significantly affect the quality of the indoor climate in terms of dust in the halls for poultry. In the frame of this research the concentration of air dust was measured by exact instrument Dust-Track aerosol monitor. Using the special impactors the PM1, PM2.5, PM4, PM10 size fractions were also measured. The obtained results of measurements were evaluated and concentrations of different size of dust particles were analyzed. Results of different indoor conditions were generalized. Based on the results of the measurements practical recommendations for the design, use and ventilation of these types of buildings were summarized in the conclusions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
15th International Scientific Conference on Engineering for Rural Development
ISBN
—
ISSN
1691-3043
e-ISSN
—
Počet stran výsledku
5
Strana od-do
45-49
Název nakladatele
Latvia University of Agriculture
Místo vydání
Jelgava; Latvia
Místo konání akce
Jelgava; Latvia
Datum konání akce
25. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—