Popis výsledku v původním jazyce
The aim of this research is an evaluation of the quality and function of ventilation equipment in basement rooms. There was analysed the function of ventilation system in relation to the quality of outdoor and indoor environment. The concentration of air dust was measured by exact instrument DustTRAK II Model 8530 aerosol monitor inside and outside the building. Using the special impactors the PM1, PM2,5, PM4, PM10 size fractions were also measured. Particles separated from the ventilation equipment were examined with SEM (scanning electron microscopy) using a microscope TESCAN MIRA 3 GMX. Obtained results of measurements were evaluated by statistical instruments and concentrations of different size of dust particles were analysed. The size of particles outlet the ventilation equipment was ca. of 55% lower than the size of the particles inlet the ventilation equipment. The difference in tested sizes of the dust particles in the ventilation equipment and outlet the ventilation equipment, i.e. in the p
Název v anglickém jazyce
Evaluation of quality and efficiency of ventilation equipment by scanning electron microscopy
Popis výsledku anglicky
The aim of this research is an evaluation of the quality and function of ventilation equipment in basement rooms. There was analysed the function of ventilation system in relation to the quality of outdoor and indoor environment. The concentration of air dust was measured by exact instrument DustTRAK II Model 8530 aerosol monitor inside and outside the building. Using the special impactors the PM1, PM2,5, PM4, PM10 size fractions were also measured. Particles separated from the ventilation equipment were examined with SEM (scanning electron microscopy) using a microscope TESCAN MIRA 3 GMX. Obtained results of measurements were evaluated by statistical instruments and concentrations of different size of dust particles were analysed. The size of particles outlet the ventilation equipment was ca. of 55% lower than the size of the particles inlet the ventilation equipment. The difference in tested sizes of the dust particles in the ventilation equipment and outlet the ventilation equipment, i.e. in the p
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
Special Issue 1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
1014-1023
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85019589853