Dust pollution in the sport facilities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F16%3A70542" target="_blank" >RIV/60460709:41310/16:70542 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dust pollution in the sport facilities
Popis výsledku v původním jazyce
The aim of this paper is to present the results of microclimatic research focused on the dust pollution in several buildings and different rooms used for sport activities at the University. The attention is paid mainly to the problems of dimensions of space, capacity and activity of sportsmen, and influence of space ventilation. In the frame of this research the concentration of air dust was measured by the exact instrument DustTRAK II Model 8530 aerosol monitor. Using the special impactors the PM1, PM2.5, PM4, PM10 size fractions were also measured. Obtained results of measurements were evaluated and concentrations of different size of dust particles were analysed. Results of different indoor conditions were generalized. Based on the results of measurements practical recommendations for the design, use and ventilation of these types of buildings were summarised in the conclusions.
Název v anglickém jazyce
Dust pollution in the sport facilities
Popis výsledku anglicky
The aim of this paper is to present the results of microclimatic research focused on the dust pollution in several buildings and different rooms used for sport activities at the University. The attention is paid mainly to the problems of dimensions of space, capacity and activity of sportsmen, and influence of space ventilation. In the frame of this research the concentration of air dust was measured by the exact instrument DustTRAK II Model 8530 aerosol monitor. Using the special impactors the PM1, PM2.5, PM4, PM10 size fractions were also measured. Obtained results of measurements were evaluated and concentrations of different size of dust particles were analysed. Results of different indoor conditions were generalized. Based on the results of measurements practical recommendations for the design, use and ventilation of these types of buildings were summarised in the conclusions.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
75-81
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—