Application of response surface design to optimise the chromatographic analysis of volatile compounds in beer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F18%3A43915564" target="_blank" >RIV/60461373:22330/18:43915564 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/full/10.1002/jib.493" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1002/jib.493</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jib.493" target="_blank" >10.1002/jib.493</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of response surface design to optimise the chromatographic analysis of volatile compounds in beer
Popis výsledku v původním jazyce
Solid-phase microextraction (SPME) combined with gas chromatography and mass spectrometry (GC–MS) is a rapid method for the analysis of different aromatic compounds in beer. However, chromatographic systems are affected by different parameters and optimization is time-consuming process, but essential for establishing optimal conditions for the quantification of analytes. An automated systemconsisting of headspace (HS)–SPME extraction combined with GC–MSwas optimized for the determination of 19 volatile compounds responsible for important flavours and off-flavours of beer. The optimisation process consisted of two steps: the SPME fibre typewas chosen, and subsequently four extraction parameters (temperature, time, sodiumchloride concentration and pH) were optimised by a central composite design model. After optimisation, standard compounds were validated with relative standard deviations not exceeding 15%rel. The square of correlation coefficient for the calibration curves was ≥0.9559, indicating a linear response and the suitability of these HS-SPME conditions.
Název v anglickém jazyce
Application of response surface design to optimise the chromatographic analysis of volatile compounds in beer
Popis výsledku anglicky
Solid-phase microextraction (SPME) combined with gas chromatography and mass spectrometry (GC–MS) is a rapid method for the analysis of different aromatic compounds in beer. However, chromatographic systems are affected by different parameters and optimization is time-consuming process, but essential for establishing optimal conditions for the quantification of analytes. An automated systemconsisting of headspace (HS)–SPME extraction combined with GC–MSwas optimized for the determination of 19 volatile compounds responsible for important flavours and off-flavours of beer. The optimisation process consisted of two steps: the SPME fibre typewas chosen, and subsequently four extraction parameters (temperature, time, sodiumchloride concentration and pH) were optimised by a central composite design model. After optimisation, standard compounds were validated with relative standard deviations not exceeding 15%rel. The square of correlation coefficient for the calibration curves was ≥0.9559, indicating a linear response and the suitability of these HS-SPME conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
21101 - Food and beverages
Návaznosti výsledku
Projekt
<a href="/cs/project/TE02000177" target="_blank" >TE02000177: Centrum pro inovativní využití a posílení konkurenceschopnosti českých pivovarských surovin a výrobků</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the Institute of Brewing
ISSN
0046-9750
e-ISSN
—
Svazek periodika
124
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
244-253
Kód UT WoS článku
000442590400006
EID výsledku v databázi Scopus
2-s2.0-85047802950