Accurate selected ion flow tube mass spectrometry quantification of ethylene oxide contamination in the presence of acetaldehyde
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F23%3A00579116" target="_blank" >RIV/61388955:_____/23:00579116 - isvavai.cz</a>
Výsledek na webu
<a href="https://hdl.handle.net/11104/0347976" target="_blank" >https://hdl.handle.net/11104/0347976</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/d3ay01036h" target="_blank" >10.1039/d3ay01036h</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accurate selected ion flow tube mass spectrometry quantification of ethylene oxide contamination in the presence of acetaldehyde
Popis výsledku v původním jazyce
In September 2020, traces of ethylene oxide (a toxic substance used as a pesticide in developing countries but banned for use on food items within the European Union) were found in foodstuffs containing ingredients derived from imported sesame seed products. Vast numbers of foodstuffs were recalled across Europe due to this contamination, leading to expensive market losses and extensive trace exposure of ethylene oxide to consumers. Therefore, a rapid analysis method is needed to ensure food safety by high-throughput screening for ethylene oxide contamination. Selected ion flow tube mass spectrometry (SIFT-MS) is a suitable method for rapid quantification of trace amounts of vapours in the headspace of food samples. It turns out, however, that the presence of acetaldehyde complicates SIFT-MS analyses of its isomer ethylene oxide. It was proposed that a combination of the H3O+ and NO+ reagent ions can be used to analyse ethylene oxide in the presence of acetaldehyde. This method is, however, not robust because of the product ion overlaps and potential interferences from other matrix species. Thus, we studied the kinetics of the reactions of the H3O+, NO+, OH- and O- ions with these two compounds and obtained their rate coefficients and product ion branching ratios. Interpretation of these experimental data revealed that the OH- anions are the most suitable SIFT-MS reagents because the product ions of their reactions with acetaldehyde (CH2CHO- at m/z 43) and ethylene oxide (C2H3O2- at m/z 59) do not overlap.
Název v anglickém jazyce
Accurate selected ion flow tube mass spectrometry quantification of ethylene oxide contamination in the presence of acetaldehyde
Popis výsledku anglicky
In September 2020, traces of ethylene oxide (a toxic substance used as a pesticide in developing countries but banned for use on food items within the European Union) were found in foodstuffs containing ingredients derived from imported sesame seed products. Vast numbers of foodstuffs were recalled across Europe due to this contamination, leading to expensive market losses and extensive trace exposure of ethylene oxide to consumers. Therefore, a rapid analysis method is needed to ensure food safety by high-throughput screening for ethylene oxide contamination. Selected ion flow tube mass spectrometry (SIFT-MS) is a suitable method for rapid quantification of trace amounts of vapours in the headspace of food samples. It turns out, however, that the presence of acetaldehyde complicates SIFT-MS analyses of its isomer ethylene oxide. It was proposed that a combination of the H3O+ and NO+ reagent ions can be used to analyse ethylene oxide in the presence of acetaldehyde. This method is, however, not robust because of the product ion overlaps and potential interferences from other matrix species. Thus, we studied the kinetics of the reactions of the H3O+, NO+, OH- and O- ions with these two compounds and obtained their rate coefficients and product ion branching ratios. Interpretation of these experimental data revealed that the OH- anions are the most suitable SIFT-MS reagents because the product ions of their reactions with acetaldehyde (CH2CHO- at m/z 43) and ethylene oxide (C2H3O2- at m/z 59) do not overlap.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-25486S" target="_blank" >GA21-25486S: Hmotnostní spektrometrie v proudové a driftové trubici s vybranými ionty s negativními ionty a dusíkem jako nosným plynem</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods: advancing methods and applications
ISSN
1759-9660
e-ISSN
1759-9679
Svazek periodika
15
Číslo periodika v rámci svazku
46
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
6435-6443
Kód UT WoS článku
001102848700001
EID výsledku v databázi Scopus
2-s2.0-85178300230