Three-phase extraction for enhancement of lipidomic analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F25%3A00639576" target="_blank" >RIV/61388963:_____/25:00639576 - isvavai.cz</a>
Výsledek na webu
<a href="https://hdl.handle.net/11104/0370001" target="_blank" >https://hdl.handle.net/11104/0370001</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Three-phase extraction for enhancement of lipidomic analysis
Popis výsledku v původním jazyce
Due to the large diversity of lipids in different biological materials, extraction is a critical step in the sample preparation process. Currently used two-phase systems extract all lipids in one phase, which often leads to a loss of the number of annotated lipid species. We optimized and evaluated a three-phase extraction system. The optimized three-phase extraction system was compared with the commonly used two-phase methyl-tert-butyl ether (MTBE) extraction. Untargeted lipidomics was performed using LC-MS with heated electrospray ionization. A total of 72 different solvent mixtures were tested to create three-phase systems. Suitable three-phase systems were formed from 21 mixtures. The ability of 12 of these mixtures to separate lipid standards was investigated in detail using a commercially available mixture of lipid standards. Lipidomic analysis showed how selected three-phase systems separate lipid classes into individual phases of the extract ion system. Finally, two solvent systems were selected for the lipidomic analysis of blood plasma. The extraction systems IO:MTBE:ACN:H2O (2:2:2:1, v/v) and IO:EtOAc:ACN:H2O (4:3:4:4, v/v) resulted in the lowest lipid loss to the aqueous phase. Moreover, they enabled the identification of a higher number of lipid species compared to the traditionally used two-phase MTBE extraction.
Název v anglickém jazyce
Three-phase extraction for enhancement of lipidomic analysis
Popis výsledku anglicky
Due to the large diversity of lipids in different biological materials, extraction is a critical step in the sample preparation process. Currently used two-phase systems extract all lipids in one phase, which often leads to a loss of the number of annotated lipid species. We optimized and evaluated a three-phase extraction system. The optimized three-phase extraction system was compared with the commonly used two-phase methyl-tert-butyl ether (MTBE) extraction. Untargeted lipidomics was performed using LC-MS with heated electrospray ionization. A total of 72 different solvent mixtures were tested to create three-phase systems. Suitable three-phase systems were formed from 21 mixtures. The ability of 12 of these mixtures to separate lipid standards was investigated in detail using a commercially available mixture of lipid standards. Lipidomic analysis showed how selected three-phase systems separate lipid classes into individual phases of the extract ion system. Finally, two solvent systems were selected for the lipidomic analysis of blood plasma. The extraction systems IO:MTBE:ACN:H2O (2:2:2:1, v/v) and IO:EtOAc:ACN:H2O (4:3:4:4, v/v) resulted in the lowest lipid loss to the aqueous phase. Moreover, they enabled the identification of a higher number of lipid species compared to the traditionally used two-phase MTBE extraction.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/LX22NPO5104" target="_blank" >LX22NPO5104: Národní institut pro výzkum metabolických a kardiovaskulárních onemocnění</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů