Assay of tyrosine hydroxylase based on high-performance
Popis výsledku v původním jazyce
An assay of L-tyrosine (Tyr) hydroxylating activity operating in lincomycin biosynthesis is described. The assay development consisted of HPLC procedure development, assessing the effect of reaction mixture components on non-enzymatic. Dopa and Tyr oxidation, and sample stability evaluation. The HPLC procedure with isocratic elution and fluorescence detection was developed and validated. The method showed a wide linear range of Dopa determination of 0.125?25 mmol/L with lower limit of quantification (LLOQ) of 0.125 mmol/L, RSD of 7.2 percent and accuracy of 101.7 percent. The studied linear range of Tyr was 15.625 mmol/L to 500 mmol/L with LLOQ of 15.625 mmol/L, RSD of 1.1percent, and accuracy of 98.1percent. Recoveries for Dopa and Tyr were 100.66 percent RSD 61472;0.89 percent and 94.76 percent RSD 61472;0.94 percent, respectively
Název v anglickém jazyce
Assay of tyrosine hydroxylase based on high-performance
Popis výsledku anglicky
An assay of L-tyrosine (Tyr) hydroxylating activity operating in lincomycin biosynthesis is described. The assay development consisted of HPLC procedure development, assessing the effect of reaction mixture components on non-enzymatic. Dopa and Tyr oxidation, and sample stability evaluation. The HPLC procedure with isocratic elution and fluorescence detection was developed and validated. The method showed a wide linear range of Dopa determination of 0.125?25 mmol/L with lower limit of quantification (LLOQ) of 0.125 mmol/L, RSD of 7.2 percent and accuracy of 101.7 percent. The studied linear range of Tyr was 15.625 mmol/L to 500 mmol/L with LLOQ of 15.625 mmol/L, RSD of 1.1percent, and accuracy of 98.1percent. Recoveries for Dopa and Tyr were 100.66 percent RSD 61472;0.89 percent and 94.76 percent RSD 61472;0.94 percent, respectively
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Chromatography
ISSN
0269-3879
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1252-1258