Monitoring of the plasma generated by a gas-puff target source
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F19%3A00505086" target="_blank" >RIV/61389005:_____/19:00505086 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1103/PhysRevAccelBeams.22.052901" target="_blank" >https://doi.org/10.1103/PhysRevAccelBeams.22.052901</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1103/PhysRevAccelBeams.22.052901" target="_blank" >10.1103/PhysRevAccelBeams.22.052901</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monitoring of the plasma generated by a gas-puff target source
Popis výsledku v původním jazyce
A 10-Hz repetition rate, Nd:YAG pulsed laser (lambda = 1064 nm, pulse energy of 0.69 J, pulse duration of 3 ns) irradiated a Xe double-stream gas-puff target source. The interaction gives rise to the formation of plasma and emission of soft x-ray and extreme ultraviolet radiation. The produced plasma was investigated and characterized by a silicon carbide (SiC) and a commercial silicon (Si) detector, applying different spectral filters. Some parameters such as the plasma stability and its evolution (time trace profile and pulse time duration) are presented and discussed, evidencing pros and cons of the employment of SiC detectors with respect to the traditional Si for laser-generated plasma diagnostic.
Název v anglickém jazyce
Monitoring of the plasma generated by a gas-puff target source
Popis výsledku anglicky
A 10-Hz repetition rate, Nd:YAG pulsed laser (lambda = 1064 nm, pulse energy of 0.69 J, pulse duration of 3 ns) irradiated a Xe double-stream gas-puff target source. The interaction gives rise to the formation of plasma and emission of soft x-ray and extreme ultraviolet radiation. The produced plasma was investigated and characterized by a silicon carbide (SiC) and a commercial silicon (Si) detector, applying different spectral filters. Some parameters such as the plasma stability and its evolution (time trace profile and pulse time duration) are presented and discussed, evidencing pros and cons of the employment of SiC detectors with respect to the traditional Si for laser-generated plasma diagnostic.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA19-02804S" target="_blank" >GA19-02804S: Nanostrukturované heteropřechody pro chemirezistory</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PHYSICAL REVIEW ACCELERATORS AND BEAMS
ISSN
2469-9888
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
052901
Kód UT WoS článku
000468230500002
EID výsledku v databázi Scopus
2-s2.0-85065875907