Use of wavelet transform for fetal phonocardiography processing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F18%3A10243216" target="_blank" >RIV/61989100:27240/18:10243216 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8710506" target="_blank" >https://ieeexplore.ieee.org/document/8710506</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IS.2018.8710506" target="_blank" >10.1109/IS.2018.8710506</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of wavelet transform for fetal phonocardiography processing
Popis výsledku v původním jazyce
This work deals with fetal phonocardiography (fPCG) processing by wavelet transform (WT). The PhysioBank database, which contains the appropriate synthetic data to test filtration functionality, was used for testing. Based on the MATLAB experiment, it was found out that the best wavelet for processing the FPCG signal using WT is the fourth order Coiflet wavelet (coif4) with decomposition degree 4. Evaluation based on determining the signal-to noise-ratio (SNR) output value, based on Bland-Atman statistics and based on calculating the sensitivity value (Se), Positive predictive value (PPV), accuracy (ACC) and Fl, which is the overall probability of correct detection of heart beats, has proved that WT is a very promising method for processing the fPCG signal for the subsequent fetal heart rate (fHR) determination.
Název v anglickém jazyce
Use of wavelet transform for fetal phonocardiography processing
Popis výsledku anglicky
This work deals with fetal phonocardiography (fPCG) processing by wavelet transform (WT). The PhysioBank database, which contains the appropriate synthetic data to test filtration functionality, was used for testing. Based on the MATLAB experiment, it was found out that the best wavelet for processing the FPCG signal using WT is the fourth order Coiflet wavelet (coif4) with decomposition degree 4. Evaluation based on determining the signal-to noise-ratio (SNR) output value, based on Bland-Atman statistics and based on calculating the sensitivity value (Se), Positive predictive value (PPV), accuracy (ACC) and Fl, which is the overall probability of correct detection of heart beats, has proved that WT is a very promising method for processing the fPCG signal for the subsequent fetal heart rate (fHR) determination.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000867" target="_blank" >EF16_019/0000867: Centrum výzkumu pokročilých mechatronických systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
9th International Conference on Intelligent Systems 2018: Theory, Research and Innovation in Applications, IS 2018 - Proceedings
ISBN
978-1-5386-7097-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
39-44
Název nakladatele
IEEE
Místo vydání
Vienna
Místo konání akce
Funchal
Datum konání akce
25. 9. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000469337900007