The paper deals with application of Kalman filter in induction motor drive using pulse-width modulation direct torque control (PWM-DTC). In the first part, the conventional PWM-DTC drive is described and Kalman filter is utilized to filter components of stator current vector those are assumed to be disturbed by white noise. The second part contains simulation results that are obtained in different cases of load torque, process and measurement noise covariances. The integral time absolute error (ITAE) performance index, undershoot, ripple of important quantities are used to compare the conventional drive structure and proposed drive structure with Kalman filter. The simulation results confirm the expected dynamic response of the proposed structure. (C) 2020. The American Society of Hematology. All Rights Reserved.
Název v anglickém jazyce
Pulse-width modulation direct torque control induction motor drive with Kalman filter
Popis výsledku anglicky
The paper deals with application of Kalman filter in induction motor drive using pulse-width modulation direct torque control (PWM-DTC). In the first part, the conventional PWM-DTC drive is described and Kalman filter is utilized to filter components of stator current vector those are assumed to be disturbed by white noise. The second part contains simulation results that are obtained in different cases of load torque, process and measurement noise covariances. The integral time absolute error (ITAE) performance index, undershoot, ripple of important quantities are used to compare the conventional drive structure and proposed drive structure with Kalman filter. The simulation results confirm the expected dynamic response of the proposed structure. (C) 2020. The American Society of Hematology. All Rights Reserved.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Telkomnika
ISSN
1693-6930
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
ID - Indonéská republika
Počet stran výsledku
8
Strana od-do
277-284
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85097903931