Amperometrický biosenzor aminooxidasy spojený s kapalinovou chromatografii pro determinaci aminů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F08%3A00005614" target="_blank" >RIV/61989592:15310/08:00005614 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Amine oxidase amperometric biosensor coupled to liquid chromatography for biogenic amines determination
Popis výsledku v původním jazyce
A selective and sensitive method is presented for biogenic amines (BA) determination. The novelty consists in coupling a highly selective electrochemical biosensor to a weak acid cation-exchange column for online detection of amines. A bienzyme design, based on a recently isolated amine oxidase from grass pea and commercial horseradish peroxidase, was used for the biosensor construction. The enzymes were co-immobilized on the surface of a graphite electrode together with the electrochemical mediator (Os-redox polymer). The electrochemical detection was performed at a low applied potential (-50 mV vs. Ag/AgCl, KCl0.1 M), where biases from interferences are minimal. The separation and determination of six BA, with relevance in food analysis (tyramine, putrescine, cadaverine, histamine, agmatine and spermidine), were investigated. Irrespective of the BA nature, the amine oxidase-based biosensor showed a linear response up to 5 mM, and its sensitivity decreases in the following order: cada
Název v anglickém jazyce
Amine oxidase amperometric biosensor coupled to liquid chromatography for biogenic amines determination
Popis výsledku anglicky
A selective and sensitive method is presented for biogenic amines (BA) determination. The novelty consists in coupling a highly selective electrochemical biosensor to a weak acid cation-exchange column for online detection of amines. A bienzyme design, based on a recently isolated amine oxidase from grass pea and commercial horseradish peroxidase, was used for the biosensor construction. The enzymes were co-immobilized on the surface of a graphite electrode together with the electrochemical mediator (Os-redox polymer). The electrochemical detection was performed at a low applied potential (-50 mV vs. Ag/AgCl, KCl0.1 M), where biases from interferences are minimal. The separation and determination of six BA, with relevance in food analysis (tyramine, putrescine, cadaverine, histamine, agmatine and spermidine), were investigated. Irrespective of the BA nature, the amine oxidase-based biosensor showed a linear response up to 5 mM, and its sensitivity decreases in the following order: cada
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microchimica Acta
ISSN
0026-3672
e-ISSN
—
Svazek periodika
163
Číslo periodika v rámci svazku
3-4
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—