Clinical assessment of the lag-time and t(max) of pellets with controlled release of glucose: in vitro/in vivo comparison using C-13-breath test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16370%2F17%3A43875577" target="_blank" >RIV/62157124:16370/17:43875577 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/17:10365883 RIV/00179906:_____/17:10365883
Výsledek na webu
<a href="http://dx.doi.org/10.1002/bdd.2086" target="_blank" >http://dx.doi.org/10.1002/bdd.2086</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/bdd.2086" target="_blank" >10.1002/bdd.2086</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Clinical assessment of the lag-time and t(max) of pellets with controlled release of glucose: in vitro/in vivo comparison using C-13-breath test
Popis výsledku v původním jazyce
Maintaining a stable glycaemia in diabetes mellitus type 1 requires flexible insulin administration and carbohydrate intake to affected individuals. In real life, there might be some situations limiting the insulin-sugar balance control, e.g. night sleep or prolonged sporting activities. Glucose pellets with a pre-determined time lag between the pellet administration and glucose release were developed to mimic a snack eaten in advance'. In this article, a C-13-glucose breath test was introduced to translate laboratory dissolution testing to clinical confirmation of the glucose release pattern using 5% abundance to differentiate the appearance of in C-13 exhaled breath. An independent two-sample t-test (p=0.20) confirmed an average clinical lag time of 300min and an in vitro time of 338min to be identical at a level of significance of =0.05. Moreover, using the same statistical method, the clinical t(max) (564min) and the in vitro t(50) (594min) were also considered identical (p=0.34). It was concluded that dissolution testing is a relevant method to determine the time lags of dosage forms with controlled release of glucose and that the C-13-glucose breath test is a suitable clinical tool for lag time verification in clinical studies.
Název v anglickém jazyce
Clinical assessment of the lag-time and t(max) of pellets with controlled release of glucose: in vitro/in vivo comparison using C-13-breath test
Popis výsledku anglicky
Maintaining a stable glycaemia in diabetes mellitus type 1 requires flexible insulin administration and carbohydrate intake to affected individuals. In real life, there might be some situations limiting the insulin-sugar balance control, e.g. night sleep or prolonged sporting activities. Glucose pellets with a pre-determined time lag between the pellet administration and glucose release were developed to mimic a snack eaten in advance'. In this article, a C-13-glucose breath test was introduced to translate laboratory dissolution testing to clinical confirmation of the glucose release pattern using 5% abundance to differentiate the appearance of in C-13 exhaled breath. An independent two-sample t-test (p=0.20) confirmed an average clinical lag time of 300min and an in vitro time of 338min to be identical at a level of significance of =0.05. Moreover, using the same statistical method, the clinical t(max) (564min) and the in vitro t(50) (594min) were also considered identical (p=0.34). It was concluded that dissolution testing is a relevant method to determine the time lags of dosage forms with controlled release of glucose and that the C-13-glucose breath test is a suitable clinical tool for lag time verification in clinical studies.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biopharmaceutics & drug disposition
ISSN
0142-2782
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
458-463
Kód UT WoS článku
000414313800002
EID výsledku v databázi Scopus
—