Lab-on-fiber optofluidic platform for in situ monitoring of drug release from therapeutic eluting polyelectrolyte multilayers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F15%3A00457459" target="_blank" >RIV/67985882:_____/15:00457459 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1364/OE.23.020132" target="_blank" >http://dx.doi.org/10.1364/OE.23.020132</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/OE.23.020132" target="_blank" >10.1364/OE.23.020132</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lab-on-fiber optofluidic platform for in situ monitoring of drug release from therapeutic eluting polyelectrolyte multilayers
Popis výsledku v původním jazyce
A lab-on-fiber (LOF) optofluidic platform that provides physiologically relevant microenvironment was developed by integrating a long period grating (LPG) coupled with high order cladding mode to achieve high index sensitivity and a liquid-tight capillary tube assembly as a microfluidic chamber for LPG to mimic physiologically relevant microenvironment. We demonstrate the utility of LOF for in situ monitoring the construction of the [chitosan (CHI)/poly (acrylic acid) (PAA)/gentamicin sulfate (GS)/PAA](n) multilayers at monolayer resolution as well as evaluating the rate of GS release at a flow rate of 0.127 mL/min at 37 degrees C in real time. We reveal that GS is released at a faster rate under the dynamic flow condition than in a static medium. Ourfindings underscore the importance of conducting drug release studies in physiologically relevant conditions
Název v anglickém jazyce
Lab-on-fiber optofluidic platform for in situ monitoring of drug release from therapeutic eluting polyelectrolyte multilayers
Popis výsledku anglicky
A lab-on-fiber (LOF) optofluidic platform that provides physiologically relevant microenvironment was developed by integrating a long period grating (LPG) coupled with high order cladding mode to achieve high index sensitivity and a liquid-tight capillary tube assembly as a microfluidic chamber for LPG to mimic physiologically relevant microenvironment. We demonstrate the utility of LOF for in situ monitoring the construction of the [chitosan (CHI)/poly (acrylic acid) (PAA)/gentamicin sulfate (GS)/PAA](n) multilayers at monolayer resolution as well as evaluating the rate of GS release at a flow rate of 0.127 mL/min at 37 degrees C in real time. We reveal that GS is released at a faster rate under the dynamic flow condition than in a static medium. Ourfindings underscore the importance of conducting drug release studies in physiologically relevant conditions
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LH11038" target="_blank" >LH11038: Chemické a biochemické senzory založené na funkcionalizovaných mikro- a nanostrukturovaných optických vlnovodech</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optics Express
ISSN
1094-4087
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
15
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
20132-20142
Kód UT WoS článku
000361035300151
EID výsledku v databázi Scopus
2-s2.0-84954473447